Problem Two: One or more objects protrude too far from the side into the circulation path causing a hazard for people who are blind or who have low vision....
Search Results "Circulation Path"
Commonly Searched Documents
-
Temporary Solutions for Election Day
-
10. Vertical Clearance at Exterior Stairs
.: protected with a cane detectable warning, such as the planter shown below or enclosed with walls so a continuous 80" high circulation path is provided for building users)?...
-
F244.5.3 Routes to Adjacent Recreation Facilities
Where a circulation path connects camping facilities and adjacent recreation facilities, at least one outdoor recreation access route shall connect camping units with mobility features to...
-
F245.4.3 Routes to Adjacent Recreation Facilities
Where a circulation path connects picnic facilities and adjacent recreation facilities, at least one outdoor recreation access route shall connect picnic units with mobility features to...
-
F244.5.3 Routes to Adjacent Recreation Facilities
Where a circulation path connects camping facilities and adjacent recreation facilities, at least one outdoor recreation access route shall connect camping units with mobility features to...
-
F245.4.3 Routes to Adjacent Recreation Facilities
Where a circulation path connects picnic facilities and adjacent recreation facilities, at least one outdoor recreation access route shall connect picnic units with mobility features to...
-
F245.4.3 Routes to Adjacent Recreation Facilities
Where a circulation path connects picnic facilities and adjacent recreation facilities, this section requires at least one outdoor recreation access route to connect picnic units with mobility...
-
F244.5.3 Routes to Adjacent Recreation Facilities
Where a circulation path connects camping facilities and adjacent recreation facilities, this section requires at least one outdoor recreation access route to connect camping units with...
-
Main Lobby
Portions of the main ticket counter, which are mounted more than 27 inches above the finished floor, protrude more than 4 inches into the circulation path. See Standards § 4.4.1....
-
Extensions
Handrail extensions are required on all new ramps but need not project into perpendicular circulation paths in alterations....
-
A4.34.2 MINIMUM REQUIREMENTS
Hence, any circulation paths among all dwelling units and among all on-site facilities should be as accessible as possible....
-
R302.2 Components
Sidewalks and other pedestrian circulation paths, or a portion of sidewalks and other pedestrian circulation paths, complying with R302.3 through R302.7; 2....
-
F248.1.1 Facilities Serving Beaches
Circulation paths; 2. Parking facilities; 3. Toilet facilities; or 4. Bathing facilities....
-
Post-Mounted Objects [§307.3]
Post-Mounted Objects [§307.3] Free-standing objects with leading edges 27” to 80” high that are mounted on posts or pylons cannot protrude more than 12” into circulation paths....
-
DETECTABLE WARNING
A standardized surface feature built in or applied to walking surfaces or other elements to warn of hazards on a circulation path. Advisory Definition of DETECTABLE WARNING....
-
Is Identification of the Path(s) to the Means of Egress Necessary?
No Special Requirements. However, the ability of a person with a cognitive disability to find and use the exits should be verified. If the person is not able to recognize and use the...
-
Is Identification of the Path(s) to the Means of Egress Necessary?
No Special Requirements. Once notified, people with a speech disability can read and follow standard exit and directional signs.
-
Is Identification of the Path(s) to the Means of Egress Necessary?
No Special Requirements. Once notified, people who are deaf or hard of hearing can read and follow standard exit and directional signs.
-
DETECTABLE WARNING
A standardized surface feature built in or applied to walking surfaces or other elements to warn of hazards on a circulation path. Advisory Definition of DETECTABLE WARNING. ...
-
Definition of "Common Use"
As revised, the definition of "common use" refers to "interior or exterior circulation paths, rooms, spaces, or elements that are not for public use and are made available for the shared...
-
Alteration
Alterations include, but are not limited to, remodeling, renovation, rehabilitation, reconstruction, historic restoration, resurfacing of circulation paths or vehicular ways, changes or...
-
106.5.5 Alteration
Alterations include, but are not limited to, remodeling, renovation, rehabilitation, reconstruction, historic restoration, resurfacing of circulation paths or vehicular ways, changes or...
-
Handrail Clearance and Cross Section [§505.5, §505.7]
Wall-mounted handrails with leading edges higher than 27” cannot protrude more than 4½” into circulation paths (§307.2)....
-
DETECTABLE WARNING
A standardized surface feature built in or applied to walking surfaces or other elements to warn persons with visual impairments of hazards on a circulation path....