The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
Search Results "Wing Wall"
-
11B-1009.4.3 Wall depth and length
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. Figure 1009.4.2 Transfer Wall Height...
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck. FIGURE 11B-1009.4.2 TRANSFER WALL HEIGHT...
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. Figure 1009.4.2 Transfer Wall Height...
-
11B-1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
11B-1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
11B-1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
Height
Height The transfer wall height must be 16 inches minimum to 19 inches maximum, measured from the deck....
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
Controls: ADA Standard Section 607.5
Section 607.5 covers the current ADA Standards bathtub controls.
-
11B-607.5 Controls
Controls, other than drain stoppers, shall be located on an end wall....
-
11B-607.5 Controls
Controls, other than drain stoppers, shall be located on an end wall....
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Side Wall: ADA Standard Section 604.5.1
Section 604.5.1 covers the current ADA Standards for side wall grab bars that are used for water closets.
-
Rear Wall: ADA Standard Section 604.5.2
Section 604.5.2 covers the current ADA Standards for rear wall grab bars that are used for water closets.