The SpectrAlert Advance series offers the broadest line of outdoor speakers and speaker strobes in the industry. From metal and plastic outdoor back boxes, to white and red plastic...
Search Results "Visual Alarm"
Commonly Searched Documents
- Honeywell SPWK/SPCWK Series Outdoor Speaker/Strobes
- TelCom Red Wall Mount Weatherproof Audible Horn Strobe - 180 cd ASWP-2475W-FR
- Honeywell SpectrAlert Advance Selectable Output Devices
- Silent Knight SpectrAlert® Advance P2WH-LF
- Silent Knight SpectrAlert® Advance P2RH-LF
-
Interconnection: ADA Standard Section 809.5.3
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation....
-
Sensory Impairments
Sensory Impairments: Employers should install lighted fire strobes and other visual or vibrating alerting devices to supplement audible alarms....
-
Prohibited Use: ADA Standard Section 809.5.4
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
General: ADA Standard Section 702.1
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter...
-
807.3.1 Alarms
807.3.1 Alarms. Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with 702 shall be provided....
-
[F] 907.5 Occupant notification systems
[F] 907.5.2 Alarm notification appliances. ......
-
807.3.1 Alarms
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with 702 shall be provided....
-
807.3.1 Alarms
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with 702 shall be provided....
-
4.28.3(8)
(8) No place in common corridors or hallways in which visual alarm signalling appliances are required shall be more than 50 ft (15 m) from the signal....
-
4.28.1 General
Alarm systems required to be accessible by 4.1 shall comply with 4.28....
- Harris Communications SafeAwake Instructional Video
-
809.5.1.1 Alarm Appliances
809.5.1.1 Alarm Appliances. Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
11B-807.3.1 Alarms
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with Section 11B-702 shall be provided....
-
11B-807.3.1 Alarms
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with Section 11B-702 shall be provided....
-
11B-807.3.1 Alarms
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with Section 11B-702 shall be provided....
-
11B-215.4 Transient lodging
Guest rooms required to comply with Section 11B-224.4 shall provide fire alarms complying with Chapter 9, Section 907.5.2.3.2, and carbon monoxide alarms, where provided, complying with...
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
11B-809.5.1.1 Alarm appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with Chapter 9, Section 907.5.2.3.4 _|Visible alarms;...