Alternative Designs. One alternative design that was used by OWP&P for less frail, ambulatory individuals was the Kohler "Precedence" bathtub (Figure 14). The tub has a...
Search Results "Plumbing Element"
-
Alternative Designs
-
O. Bathtubs
O. Bathtubs - Do bathtubs (if provided) in the designated accessible guestrooms, comply with the following:
-
2. Roll-in Shower Size
2. If there are more than 50 guestrooms/suites, are all required roll-in showers at least 30" wide by 60" long or 36" wide by 60", as configured in Figure 57 below, so persons who...
-
Q. Other Showers in Accessible Guestrooms/Suites
Q. Other Showers in Accessible Guestrooms/Suites - Accessible guestrooms/suites that are not required to have roll-in showers may have an accessible bathtub, a small shower as shown...
-
211 Drinking Fountains
211 Drinking Fountains
-
212.3 Sinks
212.3 Sinks. Where sinks are provided, at least 5 percent, but no fewer than one, of each type provided in each accessible room or space shall comply with 606. EXCEPTION: Mop or...
-
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms. Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one...
-
213.3 Plumbing Fixtures and Accessories
213.3 Plumbing Fixtures and Accessories. Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with 213.2 shall comply with 213.3....
-
213.3.1 Toilet Compartments
213.3.1 Toilet Compartments. Where toilet compartments are provided, at least one toilet compartment shall comply with 604.8.1. In addition to the compartment required to comply with...
-
213.3.2 Water Closets
213.3.2 Water Closets. Where water closets are provided, at least one shall comply with 604.
-
213.3.3 Urinals
213.3.3 Urinals. Where more than one urinal is provided, at least one shall comply with 605.
-
213.3.4 Lavatories
213.3.4 Lavatories. Where lavatories are provided, at least one shall comply with 606 and shall not be located in a toilet compartment.
-
213.3.6 Bathing Facilities
213.3.6 Bathing Facilities. Where bathtubs or showers are provided, at least one bathtub complying with 607 or at least one shower complying with 608 shall be provided.
-
224.2 Guest Rooms with Mobility Features
224.2 Guest Rooms with Mobility Features. In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table...
-
Guestrooms with Roll-in Showers
Guestrooms with Roll-in Showers Common Problem: In hotels, motels, or other lodging facilities of 50 or more sleeping rooms, no rooms with roll-in showers are provided, or the...
-
Position [§305.5]
Position [§305.5] At most elements, clear floor or ground space can be positioned for either a forward or a side approach....
-
Can doors swing into required clear floor or ground space?
Doors cannot swing into required clear floor or ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates...
-
602 Drinking Fountains
Specifications for drinking fountains in section 602 address access for people who use wheelchairs (602.2 through 602.6) and for people who do not, but who may have difficulty...
-
604 Water Closets and Toilet Compartments
Section 604 addresses access to water closets and toilet compartments. Revisions to the requirements for water closets concern: location (604.2) clearance...
-
605 Urinals
Section 604.5 provides criteria for accessible urinals, including the height and depth, clear floor space, and flush controls.
-
606 Lavatories and Sinks
Section 606 provides technical criteria for lavatories and sinks. Various scoping and technical provisions invoke these requirements for lavatories in toilet and bathing facilities...
-
Knee and Toe Clearance
Accessible lavatories and sinks must provide knee and toe clearance for a forward approach (606.2). Consistent with the proposed rule, exceptions from the requirement for forward...
-
Parallel Approach to Kitchen Sinks
Comment. Commenters recommended that a parallel approach should be allowed at kitchen sinks in spaces without a cook top or conventional range, consistent with the ANSI A117.1...
-
607 Bathtubs
Specifications for bathtubs in section 607 address clear floor space, seats, grab bars, operable parts, shower spray units, and enclosures. Changes made to this section...