The percentage of accessible rooms provided shall be consistent with the percentage of rooms required to be accessible by the applicable requirements of 6.1(1), 6.1(2), or 6.1(3), until...
Search Results "Patient Room"
-
6.1(4)(a)
-
6.1(4)(b)
(b) When patient bedrooms are being added or altered individually, and not as part of an alteration of the entire area, the altered patient bedrooms shall comply with 6.3, unless either:...
-
6.3 PATIENT BEDROOMS
Provide accessible patient bedrooms in compliance with 4. Accessible patient bedrooms shall comply with the following:...
-
6.3 Patient Bedrooms
Provide accessible patient bedrooms in compliance with 4.1 through 4.35. Accessible patient bedrooms shall comply with the following:...
-
6.3(1)
EXCEPTION: Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement in 4.13.6 for maneuvering space at the latch side of the door if the door is...
-
6.3(1)
(1) Each bedroom shall have a turning space that complies with 4.2.3, and preferably that is located near the entrance.
-
6.3(2)
In rooms with 2 beds, it is preferable that this space be located between beds....
-
6.3(2)
(2) Each one-bed room shall have a minimum clear floor space of 36 in (915 mm) along each side of the bed, and 42 in (1065 mm) between the foot of the bed and the wall....
-
6.3(3)
(3) Each bedroom shall have adequate space to provide a minimum clear floor space of 36 in (915 mm) along each side of the bed and to provide an accessible route complying with 4.3.3...
-
6.3(3)
(3) Each two-bed room shall have a minimum clear floor space of 42 in (1065 mm), preferably 48 in (1220 mm), between the foot of the bed and the wall; 36 in (915 mm) between the side of...
-
6.3(4)
(4) Each four-bed room shall have a minimum clear floor space of 48 in (1220 mm) from the foot of the bed to the foot of the opposing bed; 36 in (915 mm) between the side of the bed and...
-
6.3(5)
(5) Each bedroom shall have a door that complies with 4.13.
-
6.4 Patient Toilet Rooms
Where toilet/bath rooms are provided as a part of a patient bedroom, each patient bedroom that is required to be accessible shall have an accessible toilet/bath room that complies with 4.22...
-
6.4 PATIENT TOILET ROOMS
Provide each patient bedroom that is required to be accessible with an accessible toilet room that complies with 4.22 or 4.23....
-
Maneuvering Clearances: ADA Standard Section 404.2.4
Section 404.2.4 covers the current ADA Standards for maneuvering clearances at doors, doorways, and gates.
-
805.1 General
Medical care facility and long-term care facility patient or resident sleeping rooms required to provide mobility features shall comply with 805....
-
805.2 Turning Space
Turning space complying with 304 shall be provided within the room....
-
805.3 Clear Floor or Ground Space
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed.
-
805.4 Toilet and Bathing Rooms
Toilet and bathing rooms that are provided as part of a patient or resident sleeping room shall comply with 603....
-
11B-216.8.1 Geometric symbols
Geometric symbols shall not be required at entrances to toilet and bathing rooms located within private or semi-private rooms or spaces....
-
11B-216.8.1 Geometric symbols
Exceptions: Geometric symbols shall not be required at entrances to toilet and bathing rooms located within private or semi-private rooms or spaces....
-
11B-216.8.1 Geometric symbols
Exceptions: Geometric symbols shall not be required at entrances to toilet and bathing rooms located within private or semi-private rooms or spaces....
-
11B-216.8.1 Geometric symbols
Exceptions: Geometric symbols shall not be required at entrances to toilet and bathing rooms located within private or semi-private rooms or spaces....
-
11B-223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient bedrooms or resident sleeping rooms shall be provided...