Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
Search Results "Open Riser"
Commonly Searched Documents
-
11B-1009.6.1 Pool stairs
-
1009.6.1 Pool Stairs
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
Can stair treads and risers be perforated?
Stair treads must meet requirements for floor or ground surfaces which specify that surface openings not allow passage of a sphere more than ½ inch in diameter (§302.3)....
-
Door and Gate Opening Force: ADA Standard Section 404.2.9
Section 404.2.9 covers the current ADA Standards for door and gate opening force.
-
1011.5 Stair treads and risers
...
-
1011.5 Stair treads and risers
...
-
4.13.11* Door Opening Force
The maximum force for pushing or pulling open a door shall be as follows:...
-
1012.3 Opening limitations
Open guards shall have balusters or ornamental patterns such that a 4-inch-diameter (102 mm) sphere cannot pass through any opening up to a height of 34 inches (864 mm)....
-
Opening Force
Section 404.2.9 addresses the opening force of doors and gates....
-
Gratings [4.5.4]
ADAAG requires a maximum opening dimension of ½ inch in one direction and that elongated openings be placed so that the long dimension is perpendicular to the dominant direction of travel...
-
1018.6 Openings
This section requires openings in the surface of beach access routes and resting intervals such as spaces between boards to not allow passage of a sphere more than 1/2 inch in diameter....
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
Treads and Risers [4.9.2], Nosings [4.9.3]
Variation in riser height along a set of stairs can be a tripping hazard....
-
Elongated surface openings must be perpendicular to the dominant direction of travel, but what if there is no dominant direction of travel?
When there is no dominant direction of cross traffic, openings must be limited to ½” in both dimensions. ...
-
Open movie captioning (Section-by-Section Analysis)
The Department notes that the term “open captioning” is already referenced in the examples of auxiliary aids and services provided in § 36.303(b). ...
-
Break Out Opening: ADA Standard Section 404.3.6
Section 404.3.6 covers the current ADA Standards for the break out openings at swinging or sliding doors and gates.
-
504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524...