Handrail System for Public Areas -The puristic design concept of System circum impresses through its high degree of functionality....
Search Results "Handrail Fitting"
- HEWI System Circum Handrails
- Kee Safety Inc. ADA Safety Handrail Components
-
11B-505 Handrails
[See subsections ...]
-
11B-505 Handrails
[See subsections ...]
-
HANDRAIL
A horizontal or sloping rail intended for grasping by the hand for guidance or support.
-
HANDRAIL
A horizontal or sloping rail intended for grasping by the hand for guidance or support.
-
Non-Circular Cross Sections: ADA Standard Section 505.7.2
Section 505.7.2 covers the current ADA Standards for the non-circular cross section of handrail gripping surfaces.
-
Coat Hooks and Shelves: ADA Standard Section 222.2
Section 222.2 covers scoping requirements in the current ADA Standards for coat hooks and shelves in dressing, fitting, and locker rooms.
-
Handrail Gripping Surfaces: ADA Standard Section 1008.2.5.3.1
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
11B-505.10.3 Bottom extension at stairs
The horizontal extension of a handrail shall be 12 inches (305 mm) long minimum and a height equal to that of the sloping portion of the handrail as measured above the stair nosings....
-
11B-505.10.3 Bottom extension at stairs
The horizontal extension of a handrail shall be 12 inches (305 mm) long minimum and a height equal to that of the sloping portion of the handrail as measured above the stair nosings....
- HEWI System Lignum Multiplex Handrails
- HEWI System Lignum Protect Handrails
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
11B-505.10 Handrail extensions
In assembly areas, extensions shall not be required for ramp handrails in aisles serving seating where the handrails are discontinuous to provide access to seating and to permit crossovers...
-
11B-505.10 Handrail extensions
In assembly areas, extensions shall not be required for ramp handrails in aisles serving seating where the handrails are discontinuous to provide access to seating and to permit crossovers...
- Inpro Corporation IPC® 940 Smooth Handrail with Reveal
- Inpro Corporation IPC® 900 Handrail
- Inpro Corporation IPC® 2000 Handrail
-
11B-1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with Section 11B-505 except as modified by Section 11B-1008.2.5.3....
-
11B-1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with Section 11B-505 except as modified by Section 11B-1008.2.5.3....