Section 607.4.1.2 covers the current ADA Standards for grab bars on the control end of bathtubs with permanent seats.
Search Results "Grab Bar Clearance"
Commonly Searched Documents
-
Control End Wall: ADA Standard Section 607.4.1.2
-
Head End Wall: ADA Standard Section 607.4.2.3
Section 607.4.2.3 covers the current ADA Standards for grab bars on the head end wall of bathtubs without permanent seats.
-
11. Gap
Is the gap between the wall and the inside face of each grab bar exactly 1 1/2" to accommodate persons with disabilities who rest their forearms on the bars for stabilization so the arm...
-
8. Gap
Is the gap between the wall and the inside face of each grab bar exactly 1 1/2" to accommodate persons with disabilities who rest their forearms on the bars for stabilization so the arm...
-
Grab Bars
Grab Bars Transfer walls must have at least one grab bar....
-
Rear Wall: ADA Standard Section 604.5.2
Section 604.5.2 covers the current ADA Standards for rear wall grab bars that are used for water closets.
-
Surface Hazards: ADA Standard Section 609.5
Section 609.5 covers the current ADA Standards for the surfaces of grab bars and adjacent surfaces.
-
1009.4.5 Grab Bars
1009.4.5 Grab Bars. At least one grab bar complying with 609 shall be provided on the transfer wall....
-
1009.4.5 Grab Bars
Where one grab bar is provided, clearance shall be 24 inches (610 mm) minimum on both sides of the grab bar....
-
1009.4.5 Grab Bars
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
Grab Bars [4.16.4]
Grab Bars [4.16.4] The back grab bar is most usable from the open side. It must be 36 inches long minimum, installed with one end space a maximum of 6 inches from the side wall....
-
604.8.1.5 Grab Bars
604.8.1.5 Grab Bars. Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
604.5 Grab Bars
Grab bars for water closets shall comply with 609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
-
604.8.1.5 Grab Bars
Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
604.8.1.5 Grab Bars
Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
11B-604.5.1 Side wall
The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with...
-
Structural Strength: ADA Standard Section 609.8
Section 609.8 covers the current ADA Standards for the structural strength of grab bars.
-
4.16.4* Grab Bars
Grab bars for water closets not located in stalls shall comply with 4.26 and Fig. 29. The grab bar behind the water closet shall be 36 in (915 mm) minimum....
- 604.5.2 Rear Wall Grab Bar Location
-
11B-609.9 Alternate configuration
L-shaped or U-shaped grab bars shall be permitted....
-
Grab Bars
Grab Bars A grab bar must be provided on at least one side of each step and on the transfer platform (shown on page 16), or as a continuous grab bar serving each step and the platform...
-
11B-1009.4.5 Grab bars
Where one grab bar is provided, clearance shall be 24 inches (610 mm) minimum on both sides of the grab bar....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....