A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
Search Results "Exterior Space"
Commonly Searched Documents
-
Transfer Space: ADA Standard Section 1009.5.2
-
Exterior/ Fire Doors
Exterior/ Fire Doors A maximum opening force is not specified for exterior swing doors because the closing force required by building codes usually exceeds an "accessible" resistance....
-
217.4.4 Exterior Site Requirement
217.4.4 Exterior Site Requirement. Where four or more public pay telephones are provided on an exterior site, at least one public TTY shall be provided on the site....
-
4.9.6 Outdoor Conditions
Outdoor stairs and their approaches shall be designed so that water will not accumulate on walking surfaces.
-
4.9.6 OUTDOOR CONDITIONS
Outdoor stairs and their approaches shall be designed so that water will not accumulate on walking surfaces.
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
Clear Floor or Ground Space: ADA Standard Section 811.2
A clear floor or ground space complying with 305 shall be provided....
-
1007.7.4 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
Turning Space: ADA Standard Section 809.2.2
All rooms served by an accessible route shall provide a turning space complying with 304....
-
1007.7 Exterior area for assisted rescue
1007.7 Exterior area for assisted rescue. Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
217.4.4 Exterior Site Requirement
Where four or more public pay telephones are provided on an exterior site, at least one public TTY shall be provided on the site....
-
1132A.2 Interior doors and secondary exterior doors
1132A.2 Interior doors and secondary exterior doors....
-
1003.2.13.7.1 Openness
The exterior area of refuge shall be at least 50 percent open, and the open area above the guards shall be so distributed as to minimize the accumulation of smoke or toxic gases....
-
1007.8.1 Openness
The exterior area for assisted rescue shall be at least 50 percent open, and the open area above the guards shall be so distributed as to minimize the accumulation of smoke or toxic gases...
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
1007.7.5 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
11B-217.4.4 Exterior site requirement
Where four or more public pay telephones are provided on an exterior site, at least one public TTY shall be provided on the site....
-
11B-217.4.4 Exterior site requirement
Where four or more public pay telephones are provided on an exterior site, at least one public TTY shall be provided on the site....
-
Entrance
As used in the Guidelines, "entrance" refers to an exterior entry door....
-
Clear Floor or Ground Space: ADA Standard Section 1005.4
At each location where there are railings, guards, or handrails complying with 1005.2.1, a clear floor or ground space complying with 305 shall be provided....
-
1132A.2 Interior doors and secondary exterior doors
Except as allowed by Section 1109A.2, interior doors intended for user passage and secondary exterior doors shall comply with this section....