Doors shall not be less than 6 feet 8 inches (2032 mm) in height....
Search Results "Exterior Door"
-
1132A.3, Item 1
-
Doorways without Doors or Gates, Sliding Doors, and Folding Doors: ADA Standard Section 404.2.4.2
Section 404.2.4.2 covers the current ADA Standards for maneuvering clearances at doorways without doors or gates, sliding doors, and folding doors.
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
1132A.3, Item 2
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
1132A.3, Item 2
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors intended for user passage shall comply with this section and Section 11B-404.2....
-
1132A.3, Item 3
Swinging doors shall be capable of opening at least 90 degrees....
-
1132A.3, Item 3
Swinging doors shall be capable of opening at least 90 degrees....
-
1132A.4, Item 3
Secondary exterior doors onto decks, patios, or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
1132A.4, Item 2
Exterior landings of pervious construction (e.g., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½...
-
1132A.4, Item 2
Exterior landings of pervious construction (e.g., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
§100.201 Exterior
Exterior means all areas of the premises outside of an individual dwelling unit....
-
1132A.3, Item 4
A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable....
-
1132A.3, Item 4
A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable....
-
Door Swing: ADA Standard Section 603.2.3
Section 603.2.3 covers the current ADA Standards for door swings at clear floor space and clearances at fixtures in toilet and bathing rooms.
-
1010.1.7 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space....