The IBC specifies maximum travel distances to reach an exit....
Search Results "Exit Discharge"
Commonly Searched Documents
-
Required Means of Egress [IBC §1007.1 (2003), §1003.2.13 (2000)]
-
1009.8 Two-way communication
Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit...
-
Re: ADA Sign Products Exit Sign (6" x 3")
Product link is broken adasignproducts.goemerchant-stores.com
-
907.2.4 Group F
A manual fire alarm system shall be installed in Group F occupancies that are two or more stories in height and have an occupant load of 500 or more above or below the lowest level of exit...
-
1009.8 Two-way communication
Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit...
-
907.2.2 Group B
A manual fire alarm system shall be installed in Group B occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
- Access Board: Tactile Sign Scoping
-
Exits
Exits Scoping for entrances is based in part on the number of exits required by the applicable building or life safety code....
-
1013.4 Raised character and braille exit signs
sign with the following words as appropriate: 2.1 “EXIT STAIR DOWN” 2.2 “EXIT RAMP DOWN” 2.3 “EXIT STAIR UP” 2.4 “EXIT RAMP UP” 3....
-
SECTION 1004 EXIT ACCESS
SECTION 1004 EXIT ACCESS...
-
1004.2.1 Exit or exit access doorways required
Two exits or exit access doorways from any space shall be provided where one of the following conditions exists: The occupant load of the space exceeds the values in Table 1004.2.1...
-
207 Accessible Means of Egress
Where a required exit from an occupiable level above or below a level of accessible exit discharge is not accessible, an area of rescue assistance shall be provided on each such level (in...
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
A horizontal exit compartmentalizes a building allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated...
- DORMA 9000 Series Exit Device
-
A4.1.3(9)
A4.1.3(9) Supervised automatic sprinkler systems have built in signals for monitoring features of the system such as the opening and closing of water control valves, the power...
-
SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS
SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS...
-
SECTION 1013 EXIT SIGNS
[See subsections ...]
- Door King Inc. 'Push to Exit' Button
- BEA Inc. Product Line: ACPB Access Control Push Button (Push to Exit)
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
[See subsections ...]
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
[See subsections ...]