407.2.2.2 Visible Signals. Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
Search Results "Elevator Signal Timing"
-
407.2.2.2 Visible Signals
-
407.2.2.2 Visible Signals
Signals shall be visible from the floor area adjacent to the hall call button. EXCEPTIONS: 1....
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
Hall Lanterns [4.10.4]
Audible signals sound once for the up direction, twice for down. Visual signals provide this information to people who are deaf or hard of hearing....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
407.2.2 Hall Signals
407.2.2 Hall Signals. Hall signals, including in-car signals, shall comply with 407.2.2....
-
Audible Hall Signals
The proposed rule included a maximum frequency (1,500 Hz) for audible signals....
-
407.2.2 Hall Signals
Hall signals, including in-car signals, shall comply with 407.2.2....
-
407.2.2 Hall Signals
Hall signals, including in-car signals, shall comply with 407.2.2....
-
11B-407.2.2 Hall signals
Hall signals, including in-car signals, shall comply with Section 11B-407.2.2....
-
11B-407.2.2 Hall signals
Hall signals, including in-car signals, shall comply with Section 11B-407.2.2....
-
11B-407.2.2 Hall signals
Hall signals, including in-car signals, shall comply with Section 11B-407.2.2....
-
Signal-to-Noise Ratio: ADA Standard Section 706.5
The signal-to-noise ratio for internally generated noise in assistive listening systems shall be 18 dB minimum....
-
4.10.4 Hall Lanterns
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call....
-
407.2.1.5 Signals
407.2.1.5 Signals. Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. EXCEPTIONS: 1....
-
407.2.1.5 Signals
Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. EXCEPTIONS: 1....
-
407.2.1.5 Signals
Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. EXCEPTIONS: 1....
-
407.2.2.3 Audible Signals
407.2.2.3 Audible Signals....
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
User activation of door close (or automatic operation) cannot reduce the initial opening time of doors (3 seconds minimum) or the minimum door signal timing (based on 1.5/ ft/s travel speed...
-
407.2.2.3 Audible Signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel....
-
407.2.2.3 Audible Signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel....
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered....