Section 407.3.2 covers the current ADA Standards for elevator door operations.
Search Results "Door Control"
Commonly Searched Documents
-
Operation: ADA Standard Section 407.3.2
-
Handles, Pulls, and Knobs
Knobs that require a full hand grip and turning, including round door knobs and shower controls, do not comply because they require twisting of the wrist....
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3....
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
11B-407.4.6.4 Emergency controls
Emergency controls shall comply with Section 11B-407.4.6.4....
-
11B-411.4.6.3 Emergency controls
Emergency controls shall comply with Section 11B-407.4.6.4....
-
Symbols: ADA Standard Section 407.4.7.1.3
Section 407.4.7.1.3 covers the current ADA Standards for the designation and indicator symbols on elevator car control buttons.
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10....
-
Flush Controls: ADA Standard Section 605.4
Section 605.4 covers the current ADA Standards for urinal flush controls.
-
Doors and Gates: ADA Standard Section 410.6
Section 410.6 covers the current ADA Standards for the doors and gates of platform lifts.
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
Doors, Doorways, and Gates: ADA Standard Section 206.5
Section 206.5 covers scoping requirements in the most current ADA Standards for accessible routes to doors, doorways, and gates.
-
Buttons: ADA Standard Section 407.4.7.1
Section 407.4.7.1 covers the current ADA Standards for designations and indicators on elevator car control buttons.
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
11B-605.4 Flush controls
Flush controls shall be hand operated or automatic....
-
Doors in Series and Gates in Series: ADA Standard Section 404.2.6
Section 404.2.6 covers the current ADA Standards for doors in series and gates in series.
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-206.5 Doors, doorways, and gates
Doors, doorways, and gates providing user passage shall be provided in accordance with Section 11B-206.5....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
- Access Board: Automatic Door Controls
-
Guest Room Doors and Doorways: ADA Standard Section 224.1.2
Section 224.1.2 covers scoping requirements in the current ADA Standards for transient lodging guest room doors and doorways.