Door and gate closing speed shall comply with Section 11B-404.2.8.
Search Results "Closer Height"
-
11B-404.2.8 Closing speed
-
404.2.8 Closing Speed
Door and gate closing speed shall comply with 404.2.8.
-
404.2.8 Closing Speed
Door and gate closing speed shall comply with 404.2.8.
-
404.2.8 Closing Speed
404.2.8 Closing Speed. Door and gate closing speed shall comply with 404.2.8.
-
A4.13.11(3) Application of force
(3) Application of force: Apply force gradually so that the applied force does not exceed the resistance of the door. In high-rise buildings, air-pressure differentials may require a...
-
A4.13.11(3) Application of force
(3) Application of force: Apply force gradually so that the applied force does not exceed the resistance of the door. In high-rise buildings, air-pressure differentials may...
-
11B-404.2.8 Closing speed
Door and gate closing speed shall comply with Section 11B-404.2.8.
-
11B-404.2.8 Closing speed
Door and gate closing speed shall comply with Section 11B-404.2.8.
-
Character Height: ADA Standard Section 703.5.5
Minimum character height shall comply with Table 703.5.5....
-
11B-804.3.2 Height
Exception: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted....
-
11B-804.3.2 Height
Exception: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted....
-
Is automation of doors required?
Otherwise, closers should be set with the minimum force practicable....
-
11B-703.8.9 Height above floor
Heights of low resolution variable message sign characters shall comply with Table 11B-703.8.4, based on the size of the characters on the sign....
-
11B-703.8.9 Height above floor
Heights of low resolution variable message sign characters shall comply with Table 11B-703.8.4, based on the size of the characters on the sign....
-
11B-411.4.11.1 Height
Floor destination characters shall be 1 inch (25 mm) high minimum complying with Section 11B-703.5.3.
-
11B-411.4.11.1 Height
Floor destination characters shall be 1 inch (25 mm) high minimum complying with Section 11B-703.5.3.
-
11B-902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground.
-
11B-902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground.
-
R409.4 Height
R409.4 Height. Top of gripping surfaces of handrails shall be 865 mm (2.8 ft) minimum and 965 mm (3.2 ft) maximum vertically above walking surfaces, ramp surfaces, and stair nosings....
-
11B-703.2.5 Character height
Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
11B-703.2.5 Character height
Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground. Urinals shall be 13½ inches (343 mm) deep minimum...
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface.
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground. Urinals shall be 13½ inches (343 mm) deep minimum...