Residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and residential dwelling units required to provide communication features...
Search Results "Adaptable Features"
-
11B-233.3.5 Dispersion
-
11B-233.3.5 Dispersion
Residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and residential dwelling units required to provide communication features...
-
Residential Dwelling Units with Mobility Features: ADA Standard Section 233.3.1.1
Section 233.3.1.1 covers scoping requirements in the current ADA Standards for residential dwelling units with mobility features.
-
Section 35.151(j) Residential housing for sale to individual owners (Section-by-Section Analysis)
with the units that have those features....
-
11B-203.8 Residential facilities
In residential facilities, common use areas that do not serve residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 or adaptable...
-
ADAPTABLE
ADAPTABLE. [DSA-AC] Capable of being readily modified and made accessible. Advisory Definition of ADAPTABLE. ...
-
Guest Rooms with Communication Features: ADA Standard Section 806.3
Guest rooms required to provide communication features shall comply with 806.3. Advisory 806.3 Guest Rooms with Communication Features....
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors.
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section.
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
11B-809.7.2 Changes in level
Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with...
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no...
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors.
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no...
-
11B-809.7.2 Changes in level
Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with...
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section.
-
ADAPTABLE
Advisory Definition of ADAPTABLE. This term means that elements can be modified or adjusted to accommodate the needs of a specific user. ...
-
ADAPTABLE
Advisory Definition of ADAPTABLE. This term means that elements can be modified or adjusted to accommodate the needs of a specific user....
-
§8.3 Adaptability
Adaptability means the ability of certain elements of a dwelling unit, such as kitchen counters, sinks, and grab bars, to be added to, raised, lowered, or otherwise altered, to accommodate...
-
Adaptability
Adaptability Toilet rooms designed for use by a single occupant of a specific space, can be designed to be "adaptable" so that accessible elements can be installed when needed after construction...
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30...
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward. Glazing used in doors and panels of bathtub...
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30...