Where the first floor in a building containing residential dwelling units is a floor above grade, all units on that floor shall be adaptable....
Search Results "Adaptable Dwelling Unit (FHA)"
-
11B-233.3.1.2.3 Ground floors above grade
-
11B-233.3.1.2.3 Ground floors above grade
Where the first floor in a building containing residential dwelling units is a floor above grade, all units on that floor shall be adaptable....
-
Section 2. Single-story dwelling unit
"Single-story dwelling unit" means a dwelling unit with all finished living space located on one floor....
-
Section 3. Fair Housing Act Design and Construction Requirements
ETA Editor's Note Section 3 of the original document reprints the text of 24 CFR §100.205, which implements the Fair Housing Act's accessibility requirements. However, the...
-
11B-809.11 Washing machines and clothes dryers
Where washing machines and clothes dryers are provided in residential dwelling units with adaptable features, one of each type shall be provided....
-
11B-809.11 Washing machines and clothes dryers
Where washing machines and clothes dryers are provided in residential dwelling units with adaptable features, one of each type shall be provided....
-
4.34 DWELLING UNITS
[See subsections ...]
-
11B-233.3.4.3 Alterations to residential dwelling units with adaptable features
The building standards for residential dwelling units with adaptable features do not apply to the alteration, repair, rehabilitation or maintenance of residential dwelling units constructed...
-
11B-809.10.1 General
All toilet and bathing rooms on an accessible route within residential dwelling units with adaptable features shall comply with Sections 11B-809.7, 11B-809.8, 11B-809.10.6.4, 11B-809.10.7.3...
-
11B-809.10.1 General
All bathrooms on an accessible route within residential dwelling units with adaptable features shall comply with Sections 11B-809.7, 11B-809.8, 11B-809.10.5.2, 11B-809.10.6.4, 11B-809.10.7.3...
-
Residential Dwelling Units for Sale: ADA Standard Section 233.3.2
Section 233.3.2 covers scoping requirements in the current ADA Standards for residential dwelling units for sale.
-
18.1 Q. Is it necessary to provide usable doors when the door leads to an area of the dwelling that is not accessible, such as the door leading down to an unfinished basement...?
Within the dwelling unit, doors intended for user passage through the unit must meet the requirements for usable doors....
-
11B-233.3.1.2 Residential dwelling units with adaptable features
In public housing facilities with residential dwelling units, adaptable residential dwelling units complying with Chapter 11A, Division IV – Dwelling Unit Features shall be provided as required...
-
1.2 Q. Does the Fair Housing Act cover four one-story dwelling units that share common walls and have individual entrances?
The Fair Housing Act applies to all units in buildings consisting of four or more dwelling units if such buildings have one or more elevators; and ground floor dwelling units in other buildings...
-
Residential Dwelling Units with Communication Features: ADA Standard Section 809.5
Residential dwelling units required to provide communication features shall comply with 809.5....
-
11B-809.9 Kitchens
Kitchens shall be on an accessible route and shall comply with this section.
-
11B-809.9 Kitchens
Kitchens shall be on an accessible route and shall comply with this section.
-
Number of Accessible Bathrooms
A number of comments were received on how many bathrooms in a dwelling unit should be subject to the Act's "usable" bathroom requirement....
-
Requirement 4. Accessible route into and through the covered dwelling unit.
Section 100.205(c)(3)(i) provides that all covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises...
-
11B-224.7.2 Multi-bedroom housing units with adaptable features
Accessible dwelling units with adaptable features shall be provided as required by Section 11B-233.3.1.2....
-
(d) Outside surface at entry door
The final Guidelines also provide that at the primary entry door to a dwelling units with direct exterior access, outside landing surfaces constructed of impervious materials such as concrete...
-
29.1 Q. Is it acceptable to design a bathroom with an in-swinging 2'10 door which can be retrofitted to swing out in order to provide the necessary clear floor space in the bathroom?
A. No. The requirements in the Guidelines must be included at the time of construction. Thus, for a bathroom, there must be sufficient maneuvering space and clear floor space so that...
-
3.2 Q. If a condominium is pre-sold as a shell and the interior is designed and constructed by the buyer, are the Guidelines applicable?
The Fair Housing Act applies to design and construction of covered multifamily dwellings, regardless of whether the person doing the design and construction is an architect, builder, or...
-
11B-206.7.6 Guest rooms and residential dwelling units
Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with Section 11B-806.2 or residential dwelling units...