A camping unit is an outdoor space in a camping facility used for camping that contains outdoor constructed features, parking spaces for recreational vehicles or other vehicles, tent pads...
Search Results "Wheelchair Storage Space"
Commonly Searched Documents
- 
    
  
  F244.1 General
  
 - 
    
  
  205 Operable Parts
  
4.1.3(13) Controls and Operating Mechanisms 205 Operable Parts 4.1.3(13) Controls and operating mechanisms in accessible spaces...
 - 
    
  
  Diagonal Curb Ramps [§406.6]
  
Diagonal Curb Ramps [§406.6] If curb ramps are placed diagonally at an intersection, it is important that clear space 48” long min. is available at the bottom that is outside active...
 - 
    
  
  Elevators
  
Elevators Common Problem: Lodging facilities with more than two floors of occupiable space - including any basement levels - do not have full-size passenger elevators available for...
 - 
    
  
  Error/Omission: When a transfer shower is used, it is often larger than the required 36" x 36" size.
  
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
 - 
    
  
  11B-209.2.1 Passenger drop-off and loading zones
  
and 11B-209.2.3, shall provide at least one passenger drop-off and loading zone complying with Section 11B-503 in every continuous 100 linear feet (30480 mm) of drop-off and loading zone space...
 - 
    
  
  11B-209.2.1 Passenger drop-off and loading zones
  
and 11B-209.2.3, shall provide at least one passenger drop-off and loading zone complying with Section 11B-503 in every continuous 100 linear feet (30480 mm) of drop-off and loading zone space...
 - 
    
  
  306.2.4 Additional Clearance
  
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
 - 
    
  
  11B-306.2.1 General
  
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...
 - 
    
  
  F244.5.2.2 Routes Within Common Use and Public Use Areas
  
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within common use and public use areas serving camping units with mobility...
 - 
    
  
  F245.4.2.2 Routes Within Common Use and Public Use Areas
  
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within common use and public use areas serving picnic units with mobility...
 - 
    
  
  F208.2.3.3 Parking for Guests, Employees, and Other Non-Residents
  
Where parking spaces are provided for persons other than residents, parking shall be provided in accordance with Table F208.2. [ECTCR UFAS 4.1.1(5)(d)(iii) re visitor parking only]...
 - 
    
  
  306.2.4 Additional Clearance
  
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
 - 
    
  
  10. Drinking fountains and water coolers
  
Accessible element or space ANSI A117.1 section APPLICATION 10....
 - 
    
  
  11B-306.2.4 Additional clearance
  
Space extending greater than 6 inches (152 mm) beyond the available knee clearance at 9 inches (229 mm) above the finish floor or ground shall not be considered toe clearance....
 - 
    
  
  306.2.1 General
  
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
 - 
    
  
  201.2 Application Based on Building or Facility Use
  
Where a site, building, facility, room, or space contains more than one use, each portion shall comply with the applicable requirements for that use....
 - 
    
  
  306.2.3 Minimum Required Depth
  
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
 - 
    
  
  306.2.4 Additional Clearance
  
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
 - 
    
  
  4.5.1* General
  
Ground and floor surfaces along accessible routes and in accessible rooms and spaces including floors, walks, ramps, stairs, and curb ramps, shall be stable, firm, slip-resistant, and shall...
 - 
    
  
  4.5.1* GENERAL
  
Ground and floor surfaces along accessible routes and in accessible rooms and spaces, including floors, walks, ramps, stairs, and curb ramps, shall be stable, firm, slip-resistant, and shall...
 - 
    
  
  4.1.6(1)(g)
  
(g) Mechanical rooms and other spaces which normally are not frequented by the public or employees of the building or facility or which by nature of their use are not required by the Architectural...
 - 
    
  
  Pedestrian Access Points to a Beach
  
Access Points include parking facilities that serve beaches, dune crossings, and stairways or ramps leading from boardwalks, walkways, or parking spaces to the beach....
 - 
    
  
  306.2.4 Additional Clearance
  
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....