7.2 Technological and Scientific Considerations
imaging equipment present serious technical, scientific, and design impediments to improve accessibility of the height of machines’ transfer surfaces, mounting of transfer supports, and/or spaces...
-
4. Organization of Technical Criteria
Mammography equipment that is designed for use by patients seated in a wheelchair would have to meet the technical criteria for wheelchair spaces, changes in level at entry to the wheelchair...
-
11B-205.1 General
Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply with Section 11B-309. Exceptions: 1. ...
-
Kitchens and Kitchenettes
Section 4.34.2 of the UFAS requires a clear turning space at least 60 inches in diameter or an equivalent T-shaped turning space in kitchens....
-
11B-233.3.5 Dispersion
of the types of residential dwelling units provided, one-story residential dwelling units shall be permitted as a substitute for multi-story residential dwelling units where equivalent spaces...
-
706.1 General
On the other hand, an infrared system is typically a better choice than an FM system where confidential transmission is important because it will be contained within a given space....
-
Mounting Height and Location
Tactile signs are required to be located alongside the latch side of doors so that clear floor space at least 18 by 18 inches, centered on the tactile characters, is provided outside the...
-
1133B.7.1
If a walk or sidewalk has less than 60 inch (1525 mm) clear width, then passing spaces at least 60 inches by 60 inches (1525 mm by 1525 mm) shall be located at reasonable intervals not to...
-
Alterations
The seat of at least one spring rocker is between 11 inches (280 mm) and 24 inches (610 mm) maximum, and clear floor or ground space and maneuvering space is provided. ...
-
11B-206 Accessible routes
INTERPRETATION Section 11B-206.4.10 requires a minimum of one accessible entrance to be provided with weather protection, passenger loading zone, and vehicle pull-up space....
-
706.1 General
On the other hand, an infrared system is typically a better choice than an FM system where confidential transmission is important because it will be contained within a given space....
-
Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations Weight Scales
to Support Equipment Features Addressed in Technical Criteria Types Of Equipment To Which Technical Criteria Applies Seated in a wheelchair (M303) Wheelchair space...
-
R305 Detectable Warning Surfaces (Section-by-Section Analysis)
The dimensions for dome size and dome spacing are the same as in the 2004 ADA and ABA Accessibility Guidelines....
-
A. Exterior Routes
abrupt level changes over 1/4", and no unramped curbs that will impede access for persons who use wheelchairs, walkers and other mobility aids between... 1. ...the accessible parking space...
-
New Construction
Designers should use the Chapter 3 building blocks that address reach ranges, knee and toe clearance, clear floor space, protruding objects and operable parts when designing the space....