Accessible element or space ANSI A117.1 section APPLICATION 11....
Search Results "Parking Space Length"
Commonly Searched Documents
-
11. Toilet rooms and bathing facilities
-
Section 2. Common use areas
"Common use areas" means rooms, spaces or elements inside or outside of a building that are made available for the use of residents of a building or the guests thereof....
-
806.2 Guest Rooms with Mobility Features
The requirements in 806.2 do not include requirements that are common to all accessible spaces....
-
7.4.9 Trail Facilities
When the surface of the required clear ground space for trail facilities is not paved or is not elevated above the natural ground, slopes not steeper than 1:20 (5 percent) shall be permitted...
-
Note
Please note that this is not an exhaustive list of the elements and spaces required to be accessible per the 2013 California Building Code. ...
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
4.34.2(9)
(9) All controls in accessible spaces shall comply with 4.27....
-
Note
Please note that this is not an exhaustive list of the elements and spaces required to be accessible per the 2013 California Building Code. ...
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
Common Use Circulation Paths in Employee Work Areas [§206.2.8]
This requirement facilitates access to individual work stations within a space. Common Use Circulation Paths...
-
Additions [§202.2]
Existing elements and spaces affected by an addition are treated as alterations and qualify for certain allowances or exceptions that are not permitted in new construction....
-
Operable Parts Covered [§205]
Operable Parts Covered [§205] Compliance is required for operable parts located in accessible spaces and along accessible routes....
-
Can platform lifts be portable or provided after construction as an adaptation?
Platform lifts can be provided after construction only to provide access to raised work stations in courtrooms (sufficient space and electrical service must be provided in design to facilitate...
-
Can ramps be portable or provided after construction as an adaptation?
Ramps can be provided after construction only to provide access to raised work stations in courtrooms (sufficient space must be provided in design to facilitate installation)....
-
11B-806.2 Guest rooms with mobility features
The requirements in Section 11B-806.2 do not include requirements that are common to all accessible spaces....
-
11B-1002.2 Accessible routes
In most cases, this will be limited to areas where the accessible route leads directly to the amusement ride and where there are space limitations on the ride, not the queue line....
-
11B-809.10.6.1 Size
A water closet shall be permitted to project 12 inches (305 mm) maximum into the opening provided that 36 inches (914 mm) minimum clear space is maintained between the water closet and the...
- AJW Architectural Products U280 C-fold/Multifold Towel Dispenser - In-Wall Recessed
- Barrier Free Lifts L101-400 Series LEXA Professional Patient Lift
- KirbyBuilt Maxwell Recycled Plastic Picnic Table
- Sizewise Bari Rehab Platform
- Pilot Rock AT Series Traditional A-Frame Picnic Table With Steel Braces - Using Lumber
- Georgia-Pacific Cormatic® Automated Designer Series Towel Dispenser
- TownSteel TS8000 Grade 2 Fire Rim Device