Exception: In Group I-2, where such doors are installed across corridors, a pair of opposite swinging doors without a center mullion shall be installed having vision panels with approved...
Search Results "General Exception"
-
709.5 Openings
-
907.2 Where required
The automatic fire detectors shall be smoke detectors, except that an approved alternative type of detector shall be installed in spaces such as boiler rooms where, during normal operation...
-
4.3.11.2 Size
EXCEPTION: The appropriate local authority may reduce the minimum number of 30-inch by 48-inch (760 mm by 1220 mm) areas to one for each area of rescue assistance on floors where the occupant...
-
4.17.3 SIZE AND ARRANGEMENT
Figure 30 Toilet Stalls EXCEPTION: In instances of alteration work where provision of a standard stall (Fig. 30(a)) is structurally impracticable or where plumbing...
-
F247.4 Trail Facilities
section requires camping facilities, picnic facilities, and viewing areas provided on trails to comply with the applicable scoping requirements for the facilities in F244 through F246, except...
-
1011.3 Operable Parts
EXCEPTIONS: 1. Fire rings, grills, fireplaces, wood stoves, water hydrants, and water utility hookups shall comply with 309.4 to the extent practicable. 2....
-
1017.5 Tread Obstacles
EXCEPTION: Where the surface is other than asphalt, concrete, or boards, tread obstacles shall be permitted to not exceed 2 inches (50 mm) in height measured vertically to the highest point...
-
Clear Width [§405.5]
Ramps on these circulation paths must comply except that: the clear width can be reduced below 36” by work area equipment where it is essential to the work being performed (§405.5...
-
Van-Accessible Parking Spaces
Van-accessible parking spaces are the same as accessible parking spaces for cars except for three features needed for vans: a wider access aisle (96") to accommodate a wheelchair...
-
1132A.9 Smooth surface
Exceptions: 1. Automatic doors. 2....
-
11B-1009.2.1 Pool lift location
Exceptions: 1. Where the entire pool depth is less than 36 inches (914 mm) or greater than 48 inches (1219 mm), compliance with Section 11B-1009.2.1 shall not be required. 2....
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
Exception: Within secure perimeter of detention and correctional facilities, geometric symbols shall not be required to be ¼ inch (6.4 mm) thick....
-
1132A.9 Smooth surface
Exceptions: Automatic doors. Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at 60 degrees minimum from the horizontal....
-
206.7.5 Existing Site Constraints
This exception applies where topography or other similar existing site constraints necessitate the use of a platform lift as the only feasible alternative....
-
604.2 Location
The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
224.1.2 Guest Room Doors and Doorways
EXCEPTION: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with 806.2 shall not be required to comply with 404.2.3....
- Good Practices of Accessible Urban Development: Making Urban Environments Inclusive and Fully Accessible to ALL
- Canine Assistants
-
Clear Floor Space: ADA Standard Section 606.2
Section 606.2 covers the current ADA Standards for clear floor space at lavatories and sinks.
-
11B-201.4 Construction Support Facilities
EXCEPTION: During construction an accessible route shall not be required between site arrival points or the boundary of the area of construction and the entrance to the construction support...
-
Water Closets and Toilet Compartments for Children's Use: ADA Standard Section 604.9
Section 604.9 covers the current ADA Standards for water closets and toilet compartments for children's use.
-
11B-224.1.2 Guest room doors and doorways
Exception: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
-
11B-502.6 Identification
. ◼ Exception: Signs located within a circulation path shall be a minimum of 80 inches (2032 mm) above the finish floor or ground surface measured to the bottom of the sign....
-
11B-208.2.3 Residential facilities
These spaces must be dispersed among all types of resident parking, except where substantially equal or greater accessibility is provided in terms of distance from an accessible entrance...