Where at least one public pay telephone is provided in a public use area of a public building, at least one public TTY shall be provided in the public building in a public use area....
Search Results "Clear Floor Area"
Commonly Searched Documents
-
11B-217.4.3.1 Public buildings
-
Re: 405 Ramps
Gentlemen/Ladies: While the code requires a 60"x 60" clear landing, does it have to be square? Please see attached and advise, thank you....
-
203 General Exceptions
structures (203.6), certain areas within detention and correctional facilities (203.7) and residential facilities (203.8), employee work areas (203.9), and various spaces within recreation...
-
219.3 Receivers
Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3....
-
12. I am doing a small tenant improvement project, but I cannot afford the required accessibility improvements. Can I claim a hardship exemption?
Under the CBC, alteration projects are subject to the following compliance provisions: Area of alteration: The area of alteration must meet the accessibility provisions in accordance...
-
4. COMMON PATH OF TRAVEL ITEMS
These items include but are not limited to: • Primary building or facility entrance • Toilet and bathing facilities serving the area of alteration • Drinking fountains serving the...
-
704.3 Buildings on the same property and buildings containing courts
Exception: In court walls where opening protection is required, such protection is not required provided: Not more than two levels open into the court; The aggregate area...
-
4.1.4(9)(b)
At least 50 percent of patient toilets and bedrooms; all public use, common use or areas which may result in employment of handicapped persons....
-
Alterations and Additions [§206.2.3.1, §202.4]
An accessible route to stories or mezzanines may be required as part of an accessible path of travel to primary function areas that are altered or added (§202.4)....
-
Visual Alarms
This is especially true of toilet rooms, and study carrel areas where occupants cannot observe others leaving the facility....
-
602.7 Drinking Fountains for Standing Persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the finish floor or ground....
-
§ 1194.25(j)(3)
(3) Where any operable control is more than 10 inches and not more than 24 inches behind the reference plane, the height shall be 46 inches maximum and 15 inches minimum above the floor....
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of 1/2 inch (13 mm) under rated loading to...
-
604.8.3 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
Mirrors
Provide a mirror in the Spy City Café men's and women's toilet rooms where the bottom edge of the reflecting surface of the mirror is mounted no more than 40" above the finished floor....
-
1b
Do they have a fixed or folding seat between 17"-19" above the floor, onto which a person who uses a wheelchair may transfer to shower?...
-
H27
Does this 36-inch wide stall have horizontal grab bars on both of the side partitions that are at least 36 inches long and 33 to 36 inches above the floor?...
-
§100.201 Covered multifamily dwellings
Covered multifamily dwellings means buildings consisting of 4 or more dwelling units if such buildings have one or more elevators; and ground floor dwelling units in other buildings consisting...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...