Comment by Greg Knoop (Moderator): Thank you Roberta. And from the clinical corner here – I hear a lot of positive “Hmms” – because this is the appropriate use of an aesthetic. Do...
Search Results "PLZ Access Aisle"
Commonly Searched Documents
-
Issue 18: What design guidance on accessibility through contrast and signage attributes can be provided in the short term for persons with low vision?
-
Can audible signals for an elevator operate only when needed by a passenger who needs them through activation of dedicated “accessibility” control?
No, audible (and visible) signals required for elevators must function automatically at all times an elevator is operational. Requiring passengers to manually activate such signals...
-
BS8300:2001 Research
From basic information gathered with human participants, the researchers developed computer aided design simulations to identify clearances needed for access aisles at vehicles....
-
11B-805.4.3 Turning space
Refer to the following examples: Exam room - Exam rooms are required to provide a turning space, accessible handwashing fixture, and 36-inch wide access along the full length of each...
-
1003.1 Applicability
The general requirements specified in Sections 1003 through 1015 shall apply to all three elements of the means of egress system, in addition to those specific requirements for the exit access...
-
11B-221.3 Companion seats
People purchasing a ticket for an accessible seat may purchase up to three additional seats for their companions in the same row and these seats must be contiguous with the accessible seat...
-
Parking: ADA Standard Section 216.5
Section 216.5 covers scoping requirements in the current ADA Standards for signs at parking.
-
Vanity Counter Top Space: ADA Standard Section 806.2.4.1
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
Wading Pools: ADA Standard Section 242.3
Section 242.3 covers scoping requirements in the current ADA Standards for wading pools.
-
Looking at Cal Green 5.106.5.3, we must provide the conduits and panel capacity for future installation for the required number of spaces (2 in this case). However, it is only when the equipment is to be installed that we need to refer to CBC and CEC. Section 11B-228.3.1 also reiterates this. Therefore, we would show the location of the conduit stub outs adjacent to 2 current parking spaces and would show space on the electric panel for the future equipment – and that is all. At this time, we do not need to show the requirements for EV accessibility when equipment is installed per Chapter 11B. Is my interpretation correct?
RESPONSE: CBC Chapter 11B accessibility provisions for EVCS apply when a project consists of one or more electric vehicle charging spaces served by an electric vehicle charger or other charging...
-
11B-806.2.4.1 Vanity counter top space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
11B-224.2.2 More than fifty guest room facilities
Facilities with more than fifty guest rooms shall be treated separately for the purposes of determining the required number of accessible rooms and type of accessible bathing facility....
-
1009.6.1 Travel distance
The maximum travel distance from any accessible space to an area of refuge shall not exceed the exit access travel distance permitted for the occupancy in accordance with Section 1017.1....
-
11B-242.3 Wading pools
At least one accessible means of entry shall be provided for wading pools. Accessible means of entry shall comply with sloped entries complying with Section 11B-1009.3....
-
Transportation Vehicles: ADA Standard Section 8.
This provides information on the revisions to the ADA Standards regarding transportation vehicles.
-
Tenant Spaces: ADA Standard Section 206.4.5
Section 206.4.5 covers scoping requirements in the most current ADA Standards for accessible routes to Ttenant spaces.
- Yale Symphony® Integrated Wiegand Solution
-
2. Passenger Vessels
In June of 2013, the Board released for public comment proposed guidelines for access to ferries, cruise ships, excursion boats, and other passenger vessels under the ADA....
- Exam Tables & Scales: What Patients Say...
-
11B-233.3.1.2.6.3 Test number two, site analysis test
For a site having multiple buildings, or a site with a single building with multiple entrances, it is not required to provide a building entrance on an accessible route to all ground floor...
-
4.3.5.1 90-Degree Turn
4.3.5.1 90-Degree Turn This turning clearance is applicable for exterior and interior circulation, aisles in seating areas, ramps and other locations....
-
Outdoor Developed Areas: ADA Standard Section 9.
Review the updated information on the revisions to the ADA Standards regarding outdoor developed areas.
-
General Holding Cells and General Housing Cells: ADA Standard Section 232.2
Section 232.2 covers scoping requirements in the current ADA Standards for general holding cells and general housing cells.
-
Ground Level: ADA Standard Section 1008.2.4.1
At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....