Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
Search Results "Lavatory Clear Floor Space"
-
810.2.2 Dimensions
-
11B-225.2.3 Library book stacks
Book stacks available for public use shall be 54 inches (1372 mm) maximum above the finish floor....
-
405 Ramps
Alternate slope requirements are permitted for short ramps in existing facilities where space constraints effectively prohibit a 1:12 running slope....
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
- LaCantina Multi-slide Thermally Controlled Aluminum Sliding Door System
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
11B-411.2.1.7.4 Adjacency assignment
Exception: The most adjacent elevator serving the selected floor shall be assigned by hall call consoles located outside the elevator landing....
-
DRIVE-UP ELECTRIC VEHICLE CHARGING STATION
vehicle charging station in which use is limited to 30 minutes maximum and is provided at a location where the electric vehicle approaches in the forward direction, stops in the vehicle space...
-
12101(b)(1)
(1) to provide a clear and comprehensive national mandate for the elimination of discrimination against individuals with disabilities; Sec. 12101 note: Findings and Purposes of ADA...
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated loading to...
-
11B-225.3 Self-service storage facilities
Self-service storage facilities shall provide individual self-service storage spaces complying with these requirements in accordance with Table 11B-225.3....
-
Health Care Providers
The guidance document includes information on accessible examination rooms and the clear floor space needed adjacent to medical equipment for individuals who use mobility devices to approach...
-
Health Care Providers
The guidance document includes information on accessible examination rooms and the clear floor space needed adjacent to medical equipment for individuals who use mobility devices to approach...
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
11B-208.2.3.1 Parking for residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with Section 11B-502 shall be provided for each residential dwelling...
- LaCantina Multi-slide Aluminum Wood Sliding Door System
-
220 Automatic Teller Machines and Fare Machines
Accessible fare collection devices shall have a minimum clear opening width of 32 inches; shall permit passage of a wheelchair; and, where provided, coin or card slots and controls necessary...
-
J. Drinking Fountains
Accessible drinking fountains must have enough space for a person using a wheelchair, scooter, or other mobility device to use the drinking fountain....
-
REPAIR
The definition is clear that repair is limited to work on an item or part and does not apply to a renovation, rehabilitation or renovation to an existing building in the event of fire or...
-
11B-205.1 General
Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply with Section 11B-309. Exceptions: 1....
-
11B-205.1 General
Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply with Section 11B-309. Exceptions: 1. ...