Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
Search Results "Floor Surface"
-
11B-703.5.1 Finish and contrast
-
11B-703.6.2 Finish and contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
11B-703.7.1 Finish and contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
1134A.8, Item 1
The top of the fixture rim shall be a maximum of 34 inches (864 mm) above the finished floor....
-
407.8.2.2 Obstructed Side Reach
more than 24 inches (610 mm), beyond the vertical reference plane, the height of the operable part shall be 46 inches (1170 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
-
4.27.3* Height
Electrical and communications system receptacles on walls shall be mounted no less than 15 in (380 mm) above the floor....
-
5.5 Food Service Lines
Tray slides shall be mounted no higher than 34 in (865 mm) above the floor (see Fig. 53)....
-
Plumbed Fixtures
Non-fixed units, such as bottled water coolers, are recognized as an option in providing additional access where only one fixed unit is provided on a floor....
-
1134A.8, Item 1
The top of the fixture rim shall be a maximum of 34 inches (864 mm) above the finished floor....
-
11B-608.5.1 Reserved
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...
-
(1)(c)
long should be mounted on at least one side wall, with one end not more than 12 inches (305 mm) from the back wall, at a height between 33 inches (840 mm) and 36 inches (915 mm) above the floor...
-
PUBLIC-USE AREAS
Examples of public use areas may include a hotel lobby, movie theater, concert hall, public restroom, sales floor of a retail store, or dining room within a restaurant.◼...
-
PUBLIC-USE AREAS
Examples of public use areas may include a hotel lobby, movie theater, concert hall, public restroom, sales floor of a retail store, or dining room within a restaurant. ◼...
- ADA Solutions, Inc. Directional Bar Tile
-
105 Referenced Standards
Society of Mechanical Engineers (ASME) for various elevators and platform lifts (105.2.2) American Society for Testing and Materials (ASTM) for use zones, play equipment, and accessible surfaces...
-
1133B.7.1
SECTION 1133B GENERAL ACCESSIBILITY FOR ENTRANCES, EXITS AND PATHS OF TRAVEL 1133B.7 Walks and sidewalks. 1133B.7.1 Continuous surface. ...
-
BACKGROUND
other medical settings.1 In response, the Access Board issued a notice of proposed rulemaking2 that, among other things, would specify a maximum lower adjustable height for the transfer surface...
-
Mary Ann Hay, IALD, LEED AP, Vice President, Director, Architectural Lighting Design, Syska Hennessy Group, Inc.
Light reflecting from highly reflective surfaces. Windows. Skylights....
-
11B-403.5.1 Clear width
Except as provided in Sections 11B-403.5.2 and 11B-403.5.3, the clear width of walking surfaces shall be 36 inches (914 mm) minimum. Exceptions: 1....
-
11B-403.5.1 Clear width
Except as provided in Sections 11B-403.5.2 and 11B-403.5.3, the clear width of walking surfaces shall be 36 inches (914 mm) minimum....
-
Rear Grab Bar
The proposed rule included provisions that make clear floor space requirements at water closets more stringent by not allowing other fixtures, such as lavatories to overlap the space....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....