responsibilities for the implementation of Section 508 convened an Accessibility Forum to facilitate discussion among the EIT industry, disability advocacy groups, and assistive technology vendors on ways...
Search Results "Vehicular Way"
-
E.5. - Will agencies have a way of obtaining standardized product testing results to determine if EIT meets the Access Board’s technical provisions?
-
Parallel Parking Spaces (R309.2) (Section-by-Section Analysis)
Parallel Parking Spaces (R309.2) (Section-by-Section Analysis) Where the adjacent sidewalk or available right-of-way is more than 4.3 meters (14 feet) wide, an access aisle must be provided...
-
11B-503.2 Vehicle pull-up space
Passenger drop-off and loading zones shall provide a vehicular pull-up space 96 inches (2438 mm) wide minimum and 20 feet (6096 mm) long minimum....
-
11B-503.2 Vehicle pull-up space
Passenger drop-off and loading zones shall provide a vehicular pull-up space 96 inches (2438 mm) wide minimum and 20 feet (6096 mm) long minimum....
-
Detectable Warnings
ways (ADAAG 4.7.7)....
-
Accessible Routes from Site Arrival Points and Within Sites
way that does not provide pedestrian access....
-
F206.3 Location
This means that circulation paths, such as vehicular ways designed for pedestrian traffic, walks, and unpaved paths that are designed to be routinely used by pedestrians must be accessible...
-
R309.2.1 Wide Sidewalks
Where the width of the adjacent sidewalk or available right-of-way exceeds 4.3 m (14.0 ft), an access aisle 1.5 m (5.0 ft) wide minimum shall be provided at street level the full length...
-
11B-206.3 Location
This means that circulation paths, such as vehicular ways designed for pedestrian traffic, walks, and unpaved paths that are designed to be routinely used by pedestrians must be accessible...
-
11B-206.3 Location
This means that circulation paths, such as vehicular ways designed for pedestrian traffic, walks, and unpaved paths that are designed to be routinely used by pedestrians must be accessible...
-
11B-812.6 Vehicle spaces
Where the long dimension of vehicle spaces is parallel to the traffic flow in the adjacent vehicular way, the length of vehicle spaces shall be 240 inches (6096 mm) minimum. 2....
-
11B-812.6 Vehicle spaces
Exceptions: Where the long dimension of vehicle spaces is parallel to the traffic flow in the adjacent vehicular way, the length of vehicle spaces shall be 240 inches (6096 mm) minimum...
-
11B-308.3.1 Unobstructed
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
11B-812.4 Vertical clearance
Vehicle spaces, access aisles serving them, and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum....
-
11B-812.4 Vertical clearance
Vehicle spaces, access aisles serving them, and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum....
-
308.3.1 Unobstructed
Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
308.3.1 Unobstructed
Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
308.3.1 Unobstructed
Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
11B-308.3.1 Unobstructed
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
R208.1 Where Required
On pedestrian access routes, detectable warning surfaces indicate the boundary between pedestrian and vehicular routes where there is a flush rather than a curbed connection....
- Designing Sidewalks and Trails for Access, Part II of II: Best Practices Design Guide
-
308.3.1 Unobstructed
Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
1(2)(a)(i) Individual building test
an accessible entrance served by an accessible route when the terrain of the site is such that: (A) the slopes of the undisturbed site measured between the planned entrance and all vehicular...
-
5. What does it mean for auxiliary aids and services to be provided in “accessible formats, in a timely manner, and in such a way as to protect the privacy and independence” of a student with a disability?
public school is providing auxiliary aids and services that are necessary to ensure effective communication, they must be provided in “accessible formats, in a timely manner, and in such a way...