The location of controls shall not require reaching across burners....
Search Results "Unobstructed Reach"
-
11B-804.6.4 Range or cooktop
-
6e.
Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach? Yes _____ No _____...
-
11B-704.2.1 Clear floor or ground space
Because clear floor and ground space is required to be unobstructed, telephones, enclosures and related telephone book storage cannot encroach on the required clear floor or ground space...
-
5c.
Are the highest floor control buttons in the elevator cab mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? Yes _____ No _____...
- Mighty 400 Pool & Spa Access Lift
-
11B-606.1 General
If soap and towel dispensers are provided, they must be located within the reach ranges specified in Section 11B-308, except for those in toilet and bathing rooms which must comply with...
-
11B-606.1 General
If soap and towel dispensers are provided, they must be located within the reach ranges specified in Section 11B-308, except for those in toilet and bathing rooms which must comply with...
-
Elevator Car Controls
Specifically, the ANSI standard specifies a maximum reach height of 48 inches for forward or side reaches....
-
§382.3 Conforming alternate version
At least one of the following applies to a conforming alternative version: (1) The conforming version can be reached from the non-conforming page via an accessibility-supported mechanism...
-
§ 382.3 Conforming alternate version
At least one of the following applies to a conforming alternative version: (1) The conforming version can be reached from the non-conforming page via an accessibility-supported mechanism...
-
f-v
Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach?...
-
e-iv
Are the highest floor control buttons mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? [ADA Standards § 4.10.12 (3)] Yes No...
-
11B-904.2 Approach
the sales or service counter, locate the accessible counter close to the cash register so that a person using a wheelchair is visible to sales or service personnel and to minimize the reach...
-
11B-904.2 Approach
the sales or service counter, locate the accessible counter close to the cash register so that a person using a wheelchair is visible to sales or service personnel and to minimize the reach...
-
Accessible Routes
Accessible Routes Accessible routes are continuous, unobstructed paths connecting all accessible elements and spaces of a building or facility....
-
Transfer Steps: ADA Standard Section 1009.5.4
Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access....
- S. R. Smith Splash! Pool Lift
-
804 Kitchens and Kitchenettes
Accessible reach ranges specify a minimum height of 15 inches (308.3) for unobstructed reaches....
- Hadrian Inc. Corridor Lockers
-
11B-1009.5.4 Transfer steps
Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access. ◼...
-
11B-1009.5.4 Transfer steps
Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access. ◼...
-
11B-308.1.2 Electrical receptacle outlets
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall comply with Section 11B-308 except the low reach shall be measured to the...
-
11B-308.1.2 Electrical receptacle outlets
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall comply with Section 11B-308 except the low reach shall be measured to the...
-
11B-308.1.2 Electrical receptacle outlets
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall comply with Section 11B-308 except the low reach shall be measured to the...