Size and Arrangement [4.17.3]
- Access-Able Designs Shower Transfer Bench SH-420-2SDL
-
11B-809.10.5.3 Controls
Exception: Shower spray units are not required in bathtubs....
- Symmons Allura® Tub/Hand Shower System S-4704
-
Plan 4B: 13-Foot Wide Accessible Guest Room
Features include an alternate roll-in shower with a seat, comparable vanity, wardrobe, and door connecting to adjacent guest room. Furnishings include two beds. ...
- Bobrick Reversible Folding Shower Seat B-5181
-
11B-224.8.2 More than 50-bed facilities
When separate shower facilities are provided for men and women, at least one roll-in shower shall be provided for each group....
- Speakman Versatile ADA Handheld Shower System SM-5490-ADA
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
- Speakman Versatile Handheld Shower System SM-5060
-
4.23.4 Water Closets
If toilet stalls are provided, then at least one shall be a standard toilet stall complying with 4.17; where 6 or more stalls are provided, in addition to the stall complying with...
-
604.8.1.7 Water closet
In new construction, the accessible water closet within the wheelchair accessible compartment shall be located in the corner, diagonal to the door....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
- Symmons® Allura Tub/Hand Shower System S-4705
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
- American Standard FloWise® Commercial Shower System Kit
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
- American Specialties Folding Shower Seat 8205-L
-
C. Toilet Rooms:
PSE shall provide at least nine (9) 60-inch wide accessible toilet compartments, located in multi-user toilet rooms, and at least six (6) accessible water closets with 60-inch wide...
-
610.3.1 Rectangular Seats
The rear edge of a rectangular seat shall be 2 1/2 inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall. The side...
-
11B-610.3.1 Rectangular seats
11B-610.3.1 Rectangular seats. The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum...
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall. The side edge...