The 1991 Standards, at section 4.13.8, require the height of thresholds at doorways not to exceed ½ inch and thresholds at exterior sliding doors not to exceed ¾ inch....
Search Results "Pocket Door"
Commonly Searched Documents
-
Thresholds at Doorways
-
(4) [sic] Thresholds at exterior doors
Subject to the exceptions for thresholds and changes in level at exterior areas constructed of impervious materials, the final Guidelines continue to specify that thresholds at exterior doors...
-
H2
Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No...
-
M2
Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No...
-
B. Measuring Clear Passage at Doors
Verifying the clear passage width at standard hinged doors requires an understanding of exactly where to measure....
-
Standard Stall
The clearances required for stall doors are different than those specified for conventional passage doors and gates in 4.13.6 since partition doors are generally lighter and easier to open...
-
Restrooms Main Lobby
The restroom vestibule door does not have the required minimum of 18" maneuvering clearance on the latch side of the door. See Standards § 4.13.6. l....
-
Controls
Clear floor space at controls should be located outside the door swing....
-
Section D: Entrances
opening (one door or one active leaf of a double door) at least 32"?...
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
D. Clear Floor Space
If there is a vestibule without fully automatic doors, is there a 30"x48" clear floor space where one can be outside the swing of a hinged door (i.e.: for out-swinging doors, at least 7'...
-
Re: 404.2.6 Doors in Series and Gates in Series
My understanding is that it was written to keep wheelchair users from having to fight two doors at once. ...
- Besam SL500 A02 for sustainable automatic doors
-
C. Clear Floor Space
When there is a vestibule into the public or employee restroom that does not have fully automatic doors, is there a 30"x48" clear floor space where one can be outside the swing of a hinged...
-
Can stair handrail extensions overlap door maneuvering clearances?
No, handrails and other elements cannot overlap door maneuvering clearances....
-
11B-404.2.7 Door and gate hardware
Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles that are designed...
-
11B-404.2.7 Door and gate hardware
Exceptions: Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles...
-
11B-404.2.7 Door and gate hardware
Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles that are designed...
- Automatic sliding door systems Besam SL500
-
Doors [9.2.2(3), 9.4]
Doors [9.2.2(3), 9.4] Compliance with 4.13 is required for all doors and doorways designed to allow passage into and within all sleeping suites or other units required to be accessible...
-
F. Clear Width
Do all entry doors to accessible guestrooms and other interior doors (except doors on shallow closets) allow at least 32" of clear passage width to accommodate persons who use wheelchairs...
-
404.2.3 Doorways - Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....