The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....
Search Results "Finish"
Commonly Searched Documents
- 
    
  
  604.9.6 Dispensers
  
- 
    
  
  608.2.3 Alternate Roll-In Type Shower Compartments
  Note: inside finished dimensions measured at the center points of opposing sides Figure 608.2.3 Alternate Roll-In Type Shower Compartment Size and Clearance... 
- 
    
  
  11B-407.2.2.2 Visible signals
  Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground.... 
- 
    
  
  610.2 Bathtub Seats
  The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor.... 
- 
    
  
  602.2 Clear Floor Space
  EXCEPTION: A parallel approach complying with 305 shall be permitted at units for children’s use where the spout is 30 inches (760 mm) maximum above the finish floor or ground and is 3½... 
- 
    
  
  11B-602.2 Clear floor space  
  Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground... 
- 
    
  
  504.4 Templates (Section-by-Section Analysis)
  It is much easier to start with an accessible template as compared to adding accessibility features to otherwise finished content.... 
- 
    
  
  4.25.3 Height
  Clothes rods or shelves shall be a maximum of 54 in (1370 mm) above the finish floor for a side approach.... 
- 
    
  
  Signage
  Directional signage must meet requirements for character proportion [4.30.2] and height [4.30.3], sign finish and contrast [4.30.5] and should include the access symbol [4.30.7].... 
- 
    
  
  4.28.3(7)
  In large rooms and spaces exceeding 100 ft (30 m) across, without obstructions 6 ft (2 m) above the finish floor, such as auditoriums, devices may be placed around the perimeter, spaced... 
- 
    
  
  Verify Electrical
  VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes.... 
- 
    
  
  Verify Electrical
  VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes.... 
- 
    
  
  11B-602.2 Clear floor space
  Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground... 
- 
    
  
  11B-610.2 Bathtub seats
  The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor.... 
- 
    
  
  11B-805.6 Hand washing fixtures, lavatories and sinks
  to Section 11B-306.3.3, Exception 1 which states: "At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish... 
- 
    
  
  Updates and Other Pocket Guides
  We are currently finishing additional Pocket Guide versions covering selected state access standards. ... 
- 
    
  
  407.2.2.2 Visible Signals
  Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground.... 
- 
    
  
  604.9.6 Dispensers
  The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor.... 
- 
    
  
  602.2 Clear Floor Space
  (2), Fig. 27(c), Fig. 27(d)] EXCEPTION: A parallel approach complying with 305 shall be permitted at units for children’s use where the spout is 30 inches (760 mm) maximum above the finish... 
- 
    
  
  Tips for Communicating with Individuals with Speech Impairments
  Do not speak for the individual or attempt to finish her or his sentences.... 
- 
    
  
  407.2.2.2 Visible Signals
  Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground.... 
- 
    
  
  502.6 Identification
  Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. Advisory 502.6 Identification.... 
- 
    
  
  Signs
  Signs that provide direction to, or information, about functional spaces must only comply with requirements for character proportion, character height, and finish and contrast between the... 