Search Results "Exterior Stair"
-
4.30 SIGNAGE
-
A.4.30 SIGNAGE
[See subsections ...]
-
11B-216 Signs.
[See subsections ...]
-
Signage
Error/Omission: Where permanent room identification signage is provided, it is mounted in the wrong location. Result: People who are blind or visually impaired are trained...
-
11B-703 Signs
11B-703 Signs.
-
11B-703.4.1 Height above finish floor or ground
11B-703.4.1 Height above finish floor or ground. Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the...
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60...
-
11B-216 Signs
[See subsections ...]
-
11B-703 Signs
[See subsections ...]
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters|_, 11B-703.3 _|Braille|_,...
-
F216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5....
-
216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5....
-
216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5....
-
Line Spacing: ADA Standard Section 703.5.9
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
1007.2 Continuity and components
1007.2 Continuity and components. Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:
-
1009.2 Continuity and components
Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters|_, 11B-703.3 _|Braille|_,...
-
STAIR
STAIR. A change in elevation, consisting of one or more risers....
-
Re: 703 Signs
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
Re: 216 Signs
216.6 Entrances. Where not all entrances comply with 404, entrances complying with 404 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1....
-
Stairs and Escalators in Existing Buildings: ADA Standard Section 206.2.3.1
Section 206.2.3.1 covers the scoping requirements for accessible routes between stairs and escalators in existing buildings.