Hoistway and car doors shall comply with Section 11B-411.3....
Search Results "Door Opening Force"
Commonly Searched Documents
- 
    
  
  11B-411.3 Elevator door requirements
  
- 
    
  
  11B-411.3 Elevator door requirements
  Hoistway and car doors shall comply with Section 11B-411.3.... 
- 
    
  
  11B-411.3 Elevator door requirements
  Hoistway and car doors shall comply with Section 11B-411.3.... 
- 
    
  
  404.2.7 Door and Gate Hardware
  Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4.... 
- 
    
  
  Door Maneuvering Clearance
  Section 404.2.4 addresses maneuvering clearances at manual doors, doorways, and gates.... 
- 
    
  
  Are exit doors usable only in one direction required to comply on both sides?
  Under the ADA Standards, compliance is not required on both sides of those doors or gates that can be used in one direction only, such as exit-only doors.... 
- 
    
  
  404.2.4.1 Swinging Doors and Gates
  Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1.... 
- 
    
  
  Closers
  Closers Automated door closing is addressed by the ANSI/BHMA standards.... 
- 
    
  
  Entrances
  All door openings must provide a minimum width of 32 inches and there must also be enough room for a person using a wheelchair to maneuver to open the door, including 18 inches of clear... 
- 
    
  
  Opening Doors From a Wheelchair Video
  Requires the Registered User plan or above. Login!
- 
    
  
  404.2.1 Revolving Doors, Gates, and Turnstiles
  404.2.1 Revolving Doors, Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route.... 
- 
    
  
  D3. Door Hardware
  Is the door hardware (e.g., lever, pull, panic bar) usable with one hand without tight grasping, pinching, or twisting of the wrist?... 
- 
    
  
  11B-407.3.4 Door and signal timing
  The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/... 
- 
    
  
  11B-407.3.4 Door and signal timing
  The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/... 
- 
    
  
  1132A.8 Hand-activated door hardware
  1132A.8 Hand-activated door hardware. Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor.... 
- 
    
  
  H25
  Is the clear width of the door at least 32 inches (measured between the face of the door and the edge of the opening) when the door is open 90 degrees?... 
- 
    
  
  11B-407.3.4 Door and signal timing
  The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/... 
- 
    
  
  1132A.8 Hand-activated door hardware
  Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor.... 
- 
    
  
  1132A.8 Hand-activated door hardware
  Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor.... 
- 
    
  
  404.2.4.1 Swinging Doors and Gates
  Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1.... 
- 
    
  
  1132A.3, Item 2
  Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position.... 
- 
    
  
  1132A.3, Item 2
  Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position.... 
- 
    
  
  Thresholds: ADA Standard Section 404.3.3
  Section 404.3.3 covers the current ADA Standards for thresholds at automatic and power-assisted doors and gates. 
- 
    
  
  11B-404.3.3 Thresholds
  Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5. 
 
              