There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
Search Results "Door Closer"
-
1010.1.4 Floor elevation
-
4.35.3 Doors
All doors to accessible dressing rooms shall be in compliance with section 4.13....
-
4.10.7* Door and Signal Timing for Hall Calls
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
4.10.7* DOOR AND SIGNAL TIMING FOR HALL CALLS
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D or T = D...
-
11B-304.4 Door swing
Doors shall be permitted to swing into turning spaces....
-
11B-304.4 Door swing
Doors shall be permitted to swing into turning spaces....
-
11B-304.4 Door swing
Doors shall be permitted to swing into turning spaces....
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
- Norton 6000 Series Low Energy Operator
-
Door Maneuvering Clearance
Section 404.2.4 addresses maneuvering clearances at manual doors, doorways, and gates....
-
17.1 Q. Is it correct that only the exterior side of the main entry door of covered multifamily dwellings must meet the ANSI requirements?
The exterior side of the main entry door is part of the public and common use areas and therefore must meet ANSI A117.1 1986 specifications for doors....
-
408.3 Elevator Doors
Elevator hoistway doors shall comply with 408.3....
-
408.3 Elevator Doors
Elevator hoistway doors shall comply with 408.3....
-
Opening Force
Section 404.2.9 addresses the opening force of doors and gates....
-
408.3.1 Sliding Doors
Sliding hoistway and car doors shall comply with 407.3.1 through 407.3.3 and 408.4.1....
-
408.3.1 Sliding Doors
Sliding hoistway and car doors shall comply with 407.3.1 through 407.3.3 and 408.4.1....
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
11B-405.7.5 Doorways
Advisory 11B-405.7.5 Doors at ramp landings....
-
11B-405.7.5 Doorways
Advisory 11B-405.7.5 Doors at ramp landings....
-
Is latch-side maneuvering clearance as specified in the Standards applicable to doors with panic bars?
When latch-side clearance is required as part of the maneuvering clearances specified for a door, including on the push side of doors with a forward approach that have both a closer and...
-
Re: 404.2.4.3 Recessed Doors and Gates
Notice that the text does not match the figure for a push approach door. This may be an error in the Standards, but since the text governs, it exceeds the illustrated requirement. ...
-
404.2.3 Doorways - Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....