Measurable Design Criteria So, I get worried when things start getting written down, if they’re not clear and if they’re not measurable....
Search Results "Clear Space"
-
Mark J. Mazz, AIA: Architectural Consultant on Accessibility
-
11B-407.4.7.1.2 Location
[2010 ADAS] EXCEPTION: Where space on an existing car operating panel precludes tactile markings to the left of the controls, markings shall be placed as near to the control as possible...
-
806.2 Guest Rooms with Mobility Features
The requirements in Section 806.2 do not include requirements that are common to all accessible spaces....
-
209.2.1 Passenger Loading Zones
except those required to comply with 209.2.2 and 209.2.3, shall provide at least one passenger loading zone complying with 503 in every continuous 100 linear feet (30 m) of loading zone space...
-
R215 Passenger Loading Zones
loading zones other than transit stops are provided, at least one accessible passenger loading zone complying with R310 shall be provided for each 30 m (100.0 ft) of continuous loading zone space...
-
Q16. Must a service animal be allowed to ride in an ambulance with its handler?
However, if the space in the ambulance is crowded and the dog's presence would interfere with the emergency medical staff's ability to treat the patient, staff should make other arrangements...
-
Story
If such portion of a building does not include occupiable space, it is not considered a story for purposes of these guidelines....
-
§100.201 Common use areas
Common use areas means rooms, spaces or elements inside or outside of a building that are made available for the use of residents of a building or the guests thereof....
-
Certain Sports/ Recreation and Other Structures (§203.10 - §203.14)
Certain Sports/ Recreation and Other Structures (§203.10 - §203.14) These structures and spaces are also exempt: raised structures used solely for refereeing, judging, or...
-
Public Sector (Government) Facilities
multi-story government facilities subject to title II of the ADA except those with no more than two stories where the inaccessible story above (or below) the entry level has no public use space...
-
11B-407.4.7.1.2 Location
[2010 ADAS] EXCEPTION: Where space on an existing car operating panel precludes tactile markings to the left of the controls, markings shall be placed as near to the control as possible...
- Cybex Total Access Cable Column Exercise Machine
- Clarity Ensemble Amplified Captioned Telephone
- Merlin Elite – HD/OCR Video Magnifier
-
Scoping [4.1.2(5)]
Accessible spaces are required for visitor and employee lots according to the number provided in each lot....
-
What Does Your Event Need? Creating a Needs Assessment
attendees) Total number of attendees anticipated Number of attendees with disabilities or functional limitations anticipated Number and size of meeting rooms/exhibit space...
-
Transfer Surface Size: Equipment Used by Patients in a Seated Position (M302.2.2)
The space available for transfer on diagnostic equipment used by patients in a seated position is smaller than the space available on diagnostic equipment used by patients in a supine, prone...
-
Vehicular Route Exceptions—Sections 206.2.1 and 206.2.2 of the 2010 Standards
for accessibility within a site which provides that an ‘‘accessible route shall not be required between accessible buildings, accessible facilities, accessible elements, and accessible spaces...
-
11B-209.2.1 Passenger loading zones
with Sections 11B-209.2.2 and 11B-209.2.3, shall provide at least one passenger loading zone complying with Section 11B-503 in every continuous 100 linear feet (30480 mm) of loading zone space...
-
502.3.3 Marking
Because these requirements permit the van access aisle to be as wide as a parking space, it is important that the aisle be clearly marked....
-
11B-703.8.14 Rate of change
screen, it shall be displayed on a single screen and shall remain motionless on the screen for a minimum 3 seconds or one second minimum for every 7 characters of the message including spaces...
-
MULTI-BEDROOM HOUSING UNIT
Multi-bedroom housing units are separate from one another and from common use spaces within a building....
-
F209.2.1 Passenger Loading Zones
except those required to comply with F209.2.2 and F209.2.3, shall provide at least one passenger loading zone complying with 503 in every continuous 100 linear feet (30 m) of loading zone space...