ETA Editor's Note CBC 11B-505.10 Exception 3 is more stringent than 2010 ADAS, which allows the handrail extensions to be eliminated in alterations where they would be hazardous. ...
Search Results "Space Allowance"
-
11B-505.10 Handrail extensions
-
11B-213.3.4 Lavatories
Since the CBC path of travel obligation to remove existing barriers only allows "safe harbor" dating back to the "immediately preceding edition" (see 11B-202.4, Exception 2), existing facilities...
-
11B-206.2.6 Performance areas
including but not limited to, stages, platforms and orchestra pits, are treated as raised or lowered areas within a given story and all are required to be accessible by ramp, elevator or, when allowed...
-
11B-505.10 Handrail extensions
ETA Editor's Note CBC 11B-505.10 Exception 3 is more stringent than 2010 ADA Standards, which allows the handrail extensions to be eliminated in alterations where they would be hazardous...
-
11B-224.1.2 Guest room doors and doorways
This applies to all doors, including bathroom doors, that allow full user passage....
- Ampetronic MLD5 MultiLoop Driver Hearing System
- Ampetronic MLD7 MultiLoop Driver Hearing System
- Pilot Rock WXT and WXTH Picnic Table Using Aluminum
- Mohawk Group Kinesthetic Carpet Tiles
- Pilot Rock WUT and WUTH Picnic Table - Using Aluminum
- Mohawk Group Into It Tile Carpet Tiles
- Allegion Schlage AL-Series Mechanical Locks
- Mohawk Group Write Direction Carpet Tiles
-
11B-407.4.7.1.2 Location
[2010 ADAS] EXCEPTION: Where space on an existing car operating panel precludes tactile markings to the left of the controls, markings shall be placed as near to the control as possible...
-
806.2 Guest Rooms with Mobility Features
The requirements in Section 806.2 do not include requirements that are common to all accessible spaces....
-
209.2.1 Passenger Loading Zones
except those required to comply with 209.2.2 and 209.2.3, shall provide at least one passenger loading zone complying with 503 in every continuous 100 linear feet (30 m) of loading zone space...
-
R215 Passenger Loading Zones
loading zones other than transit stops are provided, at least one accessible passenger loading zone complying with R310 shall be provided for each 30 m (100.0 ft) of continuous loading zone space...
-
Story
If such portion of a building does not include occupiable space, it is not considered a story for purposes of these guidelines....
-
§100.201 Common use areas
Common use areas means rooms, spaces or elements inside or outside of a building that are made available for the use of residents of a building or the guests thereof....
-
Certain Sports/ Recreation and Other Structures (§203.10 - §203.14)
Certain Sports/ Recreation and Other Structures (§203.10 - §203.14) These structures and spaces are also exempt: raised structures used solely for refereeing, judging, or...
-
Public Sector (Government) Facilities
multi-story government facilities subject to title II of the ADA except those with no more than two stories where the inaccessible story above (or below) the entry level has no public use space...
-
11B-407.4.7.1.2 Location
[2010 ADAS] EXCEPTION: Where space on an existing car operating panel precludes tactile markings to the left of the controls, markings shall be placed as near to the control as possible...
-
Re: § 36.403(d) Landlord/tenant
Tenant space alterations may trigger path of travel obligations for the landlord....
-
Section 36.201(b) (Section-By-Section Analysis and Response to Comments)
For an entity to become a public accommodation when it is the lessee of space, however, the Department believes that consideration in some form must be given....