Based on the Exception, the path of travel elements and spaces under the landlord’s authority would not be subject to review or inspection....
Search Results "Electric Vehicle Charging Space"
Commonly Searched Documents
-
Private Funds Provided by Tenant
-
20.1 Q. If a covered multifamily dwelling has an individual, private garage which is attached to and serves only that dwelling, does the garage have to be accessible in terms of width and length?
only one covered multifamily dwelling are part of that dwelling unit, and are not covered by Requirement 2 of the Guidelines, which addresses accessible and usable public and common use space...
-
DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS
DIVISION 4: ACCESSIBLE ROUTES DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS 11B-501 General 11B-502 Parking Spaces...
-
4.7.10 Diagonal Curb Ramps
The bottom of diagonal curb ramps shall have 48 in (1220 mm) minimum clear space as shown in Fig. 15(c) and (d)....
-
Top Landing [§406.4]
Side flares, where provided, are intended primarily to prevent tripping hazards, not to accommodate wheelchair maneuvering at ramps (except in alterations where sufficient landing space...
-
Elevators
Elevators Common Problem: Lodging facilities with more than two floors of occupiable space - including any basement levels - do not have full-size passenger elevators available for...
-
Error/Omission: When a transfer shower is used, it is often larger than the required 36" x 36" size.
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
11B-209.2.1 Passenger drop-off and loading zones
and 11B-209.2.3, shall provide at least one passenger drop-off and loading zone complying with Section 11B-503 in every continuous 100 linear feet (30480 mm) of drop-off and loading zone space...
-
11B-209.2.1 Passenger drop-off and loading zones
and 11B-209.2.3, shall provide at least one passenger drop-off and loading zone complying with Section 11B-503 in every continuous 100 linear feet (30480 mm) of drop-off and loading zone space...
-
382.27 May a carrier require a passenger with a disability to provide advance notice in order to obtain specific services in connection with a flight?
., transportation of an electric wheelchair on a flight scheduled to be made on an aircraft with fewer than 60 seats, accommodation for a group of 10 or more passengers with a disability...
-
SAMPLE SCENARIO: POWER OUTAGE
DAY 1: A power surge causes millions of people to lose electricity. The city is gridlocked, cell service is disrupted, but landlines are working....
-
R202 Alterations and Elements Added to Existing Facilities (Section-by-Section Analysis)
This provision is based on similar provisions in the 2004 ADA and ABA Accessibility Guidelines which do not require the circulation path to altered elements or spaces to comply with the...
- Panda TS.75 Aluminum Wood Clad Thermally Broken Folding Door System
- Panda S.65 All Aluminum with Aluminum/Wood Clad Multi-Slide Door System
- Panda S.74 Aluminum Wood Clad Folding Door System
-
SELF-SERVICE STORAGE
[DSA-AC] Building or facility designed and used for the purpose of renting or leasing individual storage spaces to customers for the purpose of storing and removing personal property on...
-
306.2.4 Additional Clearance
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
-
11B-306.2.1 General
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...
-
F244.5.2.2 Routes Within Common Use and Public Use Areas
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within common use and public use areas serving camping units with mobility...
-
F245.4.2.2 Routes Within Common Use and Public Use Areas
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within common use and public use areas serving picnic units with mobility...
-
F208.2.3.3 Parking for Guests, Employees, and Other Non-Residents
Where parking spaces are provided for persons other than residents, parking shall be provided in accordance with Table F208.2. [ECTCR UFAS 4.1.1(5)(d)(iii) re visitor parking only]...
-
306.2.4 Additional Clearance
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
-
10. Drinking fountains and water coolers
Accessible element or space ANSI A117.1 section APPLICATION 10....
-
11B-306.2.4 Additional clearance
Space extending greater than 6 inches (152 mm) beyond the available knee clearance at 9 inches (229 mm) above the finish floor or ground shall not be considered toe clearance....