The controls shall be interlocked with the car brakes, propulsion system, or door, or shall provide other appropriate mechanisms or systems, to ensure that the car cannot be moved when the...
Search Results "Door Surface"
Commonly Searched Documents
-
§ 38.125(b)(2)(i) Requirements
-
11B-1002.4.4.2 Side entry
Additional space for maneuvering and a wider door will be needed where a side opening is centered on the ride....
-
1. Snow and Ice
ambulatory blind passengers often have difficulty in icy conditions, and allowing the passenger to take the driver's arm will increase both the speed and safety of the passenger's walk from the door...
-
§ 38.95(b)(2)(i) Requirements
The controls shall be interlocked with the car brakes, propulsion system, or door, or shall provide other appropriate mechanisms or systems, to ensure that the car cannot be moved when the...
-
11B-1002.4.4.2 Side entry
Additional space for maneuvering and a wider door will be needed where a side opening is centered on the ride....
-
Jean Tessmer
It is an excellent tool for laying out and placement of ADA routes, ramps, landings, random directional surfaces, and curb ramps. 1oo% compliance can be achieved when using the sliding...
-
Picnic Tables
All new picnic table installations must comply with requirements for accessible seating spaces, table clearance, slope, and surface....
-
Typical Transfer Techniques: Staff Assistance and Patient Lifts
Other individuals will need simple tools such as a transfer board (a product made of a smooth rigid material which acts as a supporting bridge between a wheelchair and another surface, along...
-
Common Requirements (R304.5) (Section-by-Section Analysis)
Grade breaks are not permitted on the surface of ramp runs and turning spaces. Surface slopes that meet at grade breaks must be flush....
-
Transfer Supports (M301.3.1, M302.3.1, and M305.2)
M305.2.1 would require the transfer supports to be located within reach of the transfer surface and not obstruct transfer onto the surface when in position....
-
Clearance in Base (M301.4.1 and M302.4.1)
would require the clearance in the base to be 44 inches wide minimum, 6 inches high minimum measured from the floor, and 36 inches deep minimum measured from the edge of the examination surface...
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
403.5.1 Clear Width
Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches (915 mm) minimum....
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
1009.5.4 Transfer Steps
The surface of the bottom tread shall extend to a water depth of 18 inches (455 mm) minimum below the stationary water level. Advisory 1009.5.4 Transfer Steps....
-
R406.3 Unobstructed Side Reach
approach to an element and the side reach is unobstructed, the high side reach shall be 1220 mm (4.0 ft) maximum and the low side reach shall be 380 mm (1.25 ft) minimum above the finish surface...
-
Built-up Curb Ramps [4.7.6]
(The surface of access aisles cannot slope more than 2% in any direction)....
-
4.1.7(3)(e)
., open books), should be no higher than 44 in (1120 mm) above the floor surface....
-
4.7.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
Wheelchair Work Measurement Method
Wheelchair work per meter values for straight and turning were determined for all test course surfaces except sand, under dry conditions using the Wheelchair Work Measurement Method in accordance...
-
Fixed tactile maps
Placement on a horizontal or near horizontal surface provides the map reader with a real world orientation....
-
6.9 Tread Obstacles
Where the surface is paved or is elevated above the natural ground, obstacles shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point....
-
Original research for ANSI A117.1 (1957 - 1961)
Buildings and Facilities Accessible to, and Usable by, the Physically Handicapped, ramps were assessed for flatness based on measuring 18 - inch increments on both edges of the ramped surface...