To educate the general public, professionals, and low vision people themselves as to the potentialities, capabilities, and needs of low vision people....
Search Results "General Exception"
Commonly Searched Documents
- Council of Citizens with Low Vision International (CCLVI)
- Wheelchair & Ambulatory Sports
-
Safe Harbor
There is an exception for existing pools, wading pools, and spas built before March 15, 2012 [See § 36.304(g)(5)] Note: Noncomplying newly constructed and altered elements may also be...
-
Safe Harbors
There is an exception for existing pools, wading pools, and spas built before March 15, 2012....
-
11B-242.2 Swimming pools
Exceptions: 1. ...
-
Platform Lifts
Original ADAAG allowed use of platform lifts where ramps or lifts are infeasible due to existing site constraints (4.1.3(5), Exception 4(d))....
-
Do facilities in remote locations have to be accessible?
If the Forest Service builds a facility, even in remote areas or areas that are difficult to access (including wilderness), the facility must be accessible, with few exceptions....
-
VII. Effective Date
The Board is considering making the 508 Standards effective six months after publication of the final rule in the Federal Register, with one exception: federal procurement of ICT products...
-
DSA IR 11B-6 MECHANICAL ONLY PROJECTS EXEMPT FROM ACCESSIBILITY REVIEW (with revisions issued through Jan. 2011)
Revised 01-01-11 Issued 02-04-08 References: California Building Code, Section 1134B.2.1, Exception 4 Discipline: Access Compliance This Interpretation of Regulations (IR)...
-
Required Means of Egress [IBC §1007.1 (2003), §1003.2.13 (2000)]
The IBC requires at least two means of egress from all spaces and buildings with few exceptions....
-
Electronic and information technology (Preamble, Section-by-Section Analysis)
Several commenters recommended that the exception for HVAC control devices and medical equipment be revised in the final rule....
-
1010.1.9.7 Delayed egress locks
Exception: In facilities housing Alzheimer's or dementia clients, a delay of not more than 30 seconds is permitted on a delayed egress door. 5....
-
11B-242.2 Swimming pools
Exceptions: 1. ...
-
239.3 Miniature Golf Course Configuration
EXCEPTION: One break in the sequence of consecutive holes shall be permitted provided that the last hole on the miniature golf course is the last hole in the sequence....
-
Compliance Dates
On or after March 15, 2012 All existing facilities of public entities and public accommodations, except pools, must comply with the 2010 Standards to the extent required under title II...
-
307.2 Protrusion Limits
EXCEPTION: Handrails shall be permitted to protrude 4 ½ inches (115 mm) maximum. Advisory 307.2 Protrusion Limits....
-
11B-206.2.2 Within a site
Exception: An accessible route shall not be required between accessible buildings, accessible facilities, accessible elements, and accessible spaces if the only means of access between...
-
408.4.1 Car Dimensions and Doors
EXCEPTIONS: 1....
-
382.101 What other boarding and deplaning assistance must carriers provide?
The only limitation on the means of providing this assistance is that hand-carrying by carrier personnel as defined in that section is prohibited, except in situations of an emergency evacuation...
-
11B-1009.5.7 Grab bars
Exception: Grab bars on transfer systems shall not be required to comply with Section 11B-609.4. FIGURE 11B-1009.5.7 GRAB BARS...
-
11B-705.1.1.2 Dome spacing
Exception: Where installed in a radial pattern, truncated domes shall have a center-to-center spacing of 1.6 inches (41 mm) minimum to 2.4 inches (61 mm) maximum....
-
11B-239.3 Miniature golf course configuration
Exception: One break in the sequence of consecutive holes shall be permitted provided that the last hole on the miniature golf course is the last hole in the sequence....
-
11B-705.1.1.3 Color and Contrast
Exception: Where the detectable warning surface does not provide a 70 percent minimum contrast with adjacent walking surfaces, a 1 inch (25 mm) wide minimum visually contrasting surface...
-
Automatic Door Break Out Openings
Section 404.3.6 of the 2010 Standards includes an exception that exempts automatic doors from the technical requirement for break out openings when accessible manual swinging doors serve...