Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
Search Results "Water Closet Clear Floor Space"
-
306.2.4 Additional Clearance
-
306.2.4 Additional Clearance
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
-
11B-306.2.4 Additional clearance
Space extending greater than 6 inches (152 mm) beyond the available knee clearance at 9 inches (229 mm) above the finish floor or ground shall not be considered toe clearance....
-
11B-306.2.4 Additional clearance
Space extending greater than 6 inches (152 mm) beyond the available knee clearance at 9 inches (229 mm) above the finish floor or ground shall not be considered toe clearance....
-
306.2.4 Additional Clearance
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
- Access-Able Designs Portable Clamp-On Tub Seat SH-426
- Tobin Passage Levers Door Hardware
- LaCantina Multi-slide Thermally Controlled Aluminum Sliding Door System
-
QUESTION: WHAT LIMITATIONS CAN A PVO IMPOSE WITH RESPECT
TO CARRYING A SERVICE ANIMAL?
* For example, a PVO could impose a legitimate safety requirement that a service dog not be permitted to enter a sauna or steam room, sit on any surface other than the floor, or join...
-
Shower Threshold
The Board retained the ½ inch threshold height since positioning for transfer to the seat of transfer showers can be aided where a close approach enables footrests to clear the threshold...
-
Primary Function
Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, corridors, and restrooms are not areas containing a primary function...
-
11B-233.3.6 Graduate student and faculty housing at a place of education
facilities, including, but not limited to, the provisions in sections 233 and 809. 1) In sleeping rooms with more than 25 beds covered by this part, a minimum of 5% of the beds shall have clear...
-
11B-233.3.6 Graduate student and faculty housing at a place of education
facilities, including, but not limited to, the provisions in sections 233 and 809. 1) In sleeping rooms with more than 25 beds covered by this part, a minimum of 5% of the beds shall have clear...
-
Executive Summary
high and how low wheeled mobility device users can transfer to a platform above and below their mobility device seat, how high and how low users can transfer between two platform steps, clear...
-
4. My pool already existed before the effective date of the new rule. What am I required to do to provide pool access to customers with mobility disabilities?
The 2010 Standards for pool lifts require lifts to be fixed and to meet additional requirements for location, size of the seat, lifting capacity, and clear floor space....
-
Site Constraints
This is intended to cover altered facilities where limited space or other constraints preclude construction of a complying ramp....
-
306.3.1 General
Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3....
-
502.6 Identification
Parking space identification signs shall include the International Symbol of Accessibility complying with 703.7.2.1....
-
1007.1 Accessible means of egress required
Accessible spaces shall be provided with not less than one accessible means of egress....
-
ETA Public Telephone Summary Chart and Survey Instructions
. [4.1.3(17)(a)] b. 1 per floor, when 1 bank is provided on this floor [4.1.3(17)(a)] c. 1 per bank, when 2 or more banks are provided on this floor....
- Bradley 2-Station Express Lavatory System MG-2
- Bradley 2-Station Express Lavatory System SS-2N
- Bradley 3-Station Express Lavatory System SS-3N
- Bradley 3-Station Express Lavatory System MG-3