Transfer Supports A means of support is required when transferring into the entry or seat of a play component....
Search Results "Seating Space"
Commonly Searched Documents
-
Transfer Supports
-
Boarding Assistance
are completely immobile, ask carrier personnel to provide a wheelchair to transport you to and from the gate, a lift (if necessary), and assistance transferring from an aisle chair to a seat...
-
III-7.7000 Alterations
Entities are permitted to -- (a) Install only one accessible unisex bathroom per floor; (b) Cluster wheelchair seating in altered assembly areas; (c) Use platform lifts as part...
-
Assistive Powered Scooters
These scooters have a tiller for steering and a comfortable seat, usually with a back and armrests....
-
Bathtubs (ADAAG 4.20)
ADA Accessibility Guidelines for bathtubs are predicated on the use of a conventional residential bathtub by individuals who independently transfer from a wheelchair directly to a tub seat...
-
1015.2 Where required
In assembly seating areas at cross aisles in accordance with Section 1029.12. Elevated facility observation station access hatches at detention facilities....
-
11B-1009.2.7 Operation
The lift shall be stable and not permit unintended movement when a person is getting into or out of the seat. [2010 ADA Standards] 1009.2.7 Operation....
-
16. If a play surface is replaced with an accessible surface and the existing ground level play components are not accessible, do the components need to be replaced?
If the alteration to the play area only involves the surfacing, only the surface along accessible routes, clear floor or ground spaces, and maneuvering spaces must comply with the ASTM F...
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
R403 Operable Parts (Section-by-Section Analysis)
operable parts apply to operable parts on accessible pedestrian signals and pedestrian pushbuttons (see R209) and parking meters and parking pay stations that serve accessible parking spaces...
-
406.6 Diagonal Curb Ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway....
-
213.3.1 Toilet Compartments
A toilet compartment is a partitioned space that is located within a toilet room, and that normally contains no more than one water closet....
-
1016.9 Protruding Objects
This section requires constructed elements on outdoor recreation access routes, resting intervals, and passing spaces to comply with the technical requirements for protruding objects in...
-
Employee Work Area
All or any portion of a space used only by employees and used only for work. Corridors, toilet rooms, kitchenettes and break rooms are not employee work areas....
-
Self-Service Storage
Building or facility designed and used for the purpose of renting or leasing individual storage spaces to customers for the purpose of storing and removing personal property on a self-service...
-
M305.3.1.1 Horizontal Position
The length of gripping surfaces on horizontal standing supports shall be 4 inches (100 mm) minimum except for diagnostic equipment containing a wheelchair space which shall comply with M305.3.1.2...
-
1133A.2, Item 1
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows a parallel approach by a person in a wheelchair shall be provided at the range or cooktop....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
Can a disabled non-EV driver park in an ADA EVSE spot?
Vehicles left in EVCS spaces must be connected for charging purposes. DSA understands this applies to accessible EVCS too....
-
711.4.3.1 Noncombustible penetrating items
Noncombustible penetrating items that connect not more than three stories are permitted provided that the annular space is filled with an approved noncombustible material to resist the free...
-
705.1.3 Contrast
Figure 705.1 Size and Spacing of Truncated Domes...
-
§ 36.406(d)(1)
(1) In sleeping rooms with more than 25 beds covered by this section, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....