Exceptions: The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (914 mm...
Search Results "Lavatory Clear Floor Space"
-
11B-604.5.2 Rear wall
-
Section 2. Accessible route
"Accessible route" means a continuous unobstructed path connecting accessible elements and spaces in a building or within a site that can be negotiated by a person with a severe disability...
-
PATH OF TRAVEL
(A) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
Dispensers: ADA Standard Section 604.7
Section 604.7 covers the current ADA Standards for toilet paper dispensers.
-
C) Accessible Entrance
The accessible entrance must also connect to an interior accessible route leading to the space or spaces where the program is located....
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
11B-605.5.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side...
- Department of Homeland Security
- Innerface ARQ Interior Sign Frame System
-
Feature 3 - Building Entrance
An accessible entrance must provide at least one accessible door with maneuvering space, accessible door hardware, and enough clear width to allow people who use crutches, canes, walkers...
-
H. Men's Spa and Fitness Center Locker Room
Clear space sufficient to allow a person using a wheelchair to make a parallel transfer onto the bench will be provided. 2010 Standards §§ 222.1, 305, 803.4, and 903....
-
1.1.1
Although ramps with a slope slightly less than 1:12 take up more floor space, the negligible loss in usable space will more than compensate for potential problems caused by rebuilding or...
- Inclinator VL Vertical Platform Lift
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
11B-502.6.3 Location
A parking space identification sign shall be visible from each parking space....
-
J. Bedside Clearance
Regarding maneuvering space around the bed(s) in the accessible guestrooms... ...in accessible guestrooms with one bed, is there at least a 36" wide route on each side of the bed to allow...
-
d. ii.
hand and does not require tight grasping and twisting actions of the wrist to operate at the following locations: (1) Main Lobby men's and women's toilet stall doors; (2) Second Floor...
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
- Stanley Access Technologies Dura-Care 7000 Manual Door System
-
Footrests and Armrests: ADA Standard Section 1009.2.6
If provided, the armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised (load) position....
-
11B-810.9 Escalators
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 and shall have a clear width of 32 inches (813 mm) minimum....
-
11B-810.9 Escalators
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 and shall have a clear width of 32 inches (813 mm) minimum....
- LaCantina Aluminum Thermally Controlled Slider System