(2) to provide clear, strong, consistent, enforceable standards addressing discrimination against individuals with disabilities;...
Search Results "Urinal Clear Floor Space"
-
12101(b)(2)
-
R407.6.3 Length
The landing clear length shall be 1.5 m (5.0 ft) long minimum....
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum....
- Activar JL Industries Ambassador Series 1017F10 Steel Fire Extinguisher Cabinets
- Phonic Ear HearIt Media Wireless Amplifier for Televisions and Mobile Telephones
-
e-iv
Are the highest floor control buttons mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? [ADA Standards § 4.10.12 (3)] Yes No...
-
Initial Measures and Transfer Setup
The device seat to floor height was measured as the linear distance between the front of the seat, center-line point on top of the cushion (if present) and the floor (Figure 3 left). ...
-
4. Getting What You Need During Your Visit
Do you have an exam table that lowers to 18 inches from the floor or lower so that I can get on it independently?...
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
R407.6.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
Complainant No. 2
HIV and other blood borne pathogens—should eliminate any risk of transmission to the urologist or his staff, but the urologist said that he could not be sure that blood was not in the urine...
- Gamco Automatic Wall-Mounted Foam Soap Dispenser - G-950FA
-
4.34.6.4(3)
(3) Counter thickness and supporting structure shall be 2 in (50 mm) maximum over the required clear area....
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
TTYs
specifications include a requirement that the operable parts of both the TTY and the telephone be accessible according to section 309, which specifies accessible reach ranges, and provide clear...
-
A. Question 1: Applicability of Section 904.4.1’s Exception
Section 904.4.1 and its exception both require that a sales or service counter be “36 inches (915 mm) high maximum above the finish floor,” and Section 904.4.1 further requires that a sales...