Guards shall form a protective barrier not less than 42 inches (1067 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or adjacent seatboard....
Search Results "Floor Surface"
Commonly Searched Documents
-
1012.2 Height
-
Protruding Objects [1016.9]
To prevent injuries to people who are blind or have low vision, whenever possible, maintain the vertical clearance free of tree branches a minimum of 80 inches above the ground surface along...
-
1009.4.5 Grab Bars
The top of the gripping surface shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above transfer walls....
-
Signs
Standards) § 4.1.3(16)(a): Raised and Braille letters or numbers (Standards § 4.30.4); Mounting location (§ 4.30.6); Color contrast (§ 4.30.5); and Non-glare surface...
-
4.16.3 Height
Whereas the rationale for seat height in ADAAG is to provide a surface that is at or slightly below the wheelchair seat in order to accommodate a sliding transfer, the rationale in eldercare...
-
Referenced Standards [§105]
elements, including automated doors (ANSI/BHMA standards), means of egress (IBC), fire alarms (NFPA National Fire Alarm Code), elevators and platform lifts (ASME Safety Code), and play surfaces...
-
11B-705.1.2.3 Islands or cut-through medians
cut-through less 2 inches (51 mm) maximum on each side, placed at the edges of the pedestrian island or cut-through median, and shall be separated by 24 inches (610 mm) minimum of walking surface...
-
11B-812.7.2 Marking
The color of the borderlines, hatched lines, and letters shall contrast with that of the surface of the access aisle....
-
Comparison of Single-User Toilet Room Layouts: 2A, 2B, and 2C
The in-swinging door increases overall room size because it cannot swing over the required clear floor space at any accessible fixture, (see section 4.22.2 of the 1991 Standards)....
-
Components (M303.4)
M303.4.1 would require the height of the breast platform to be 30 inches (760 mm) high minimum and 42 inches (1065 mm) high maximum above the floor when mammography equipment is used by...
-
Weight Scales
Unit costs are presented for wheelchair scales with raised platforms and with flush platforms in the floor....
- Access-Able Designs Stationary Dressing Bench DST-101
-
Clear Tread Width and Passing Spaces for Outdoor Recreation Access Routes
Clear tread width means the width of the traveled surface on the ground and also above the ground between obstacles (figure 40)....
-
Medical Device Manufacturers
Many medical device manufacturers currently incorporate accessible features in some of their products such as patient support surfaces that are height adjustable, transfer and positioning...
-
Mark J. Mazz, AIA: Architectural Consultant on Accessibility
taking architectural photography tries to show daylight, the easiest way they convince people they’ve got beautiful daylight coming in is they show the contrasting shadows that hit the floor...
- Panda IS.14 Aluminum Wood Clad IMPACT Lift & Slide System
- Kuriki 2-in-One Paper Holder
- AD Systems’ Exam Room Doors
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
610.2 Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
Adaptability
Rooms need to be designed to provide required clear floor space at fixtures, turning space, and door clearance....