Search Results "Floor Surface"
-
Instrumentation for Analysis
-
11B-812.7.2 Marking
The color of the borderlines, hatched lines, and letters shall contrast with that of the surface of the access aisle....
-
1018.2 Aisles in assembly spaces
for applications listed in Section 1.9.1 regulated by the Division of the State Architect-Access Compliance, shall also comply with Chapter 11A or Chapter 11B, Section 11B-403 _|Walking Surfaces...
-
11B-604.5.2 Rear wall
The gripping surface of the grab bar must be available for the entire 36-inch length without interruption....
-
III-4.4100 General
Deep pile carpeting on floors and unpaved exterior ground surfaces often are a barrier to access by people who use wheelchairs and people who use other mobility aids, such as crutches....
-
Resting Intervals [1017.8]
When the surface of the resting interval is constructed of concrete, asphalt, or boards, the slope of the resting interval must be no steeper than 1:48 (2 percent) in any direction....
-
Dune Crossings [1018.10]
The handrails must be continuous at a height of 34 to 38 inches above the walking surface along both sides of the dune crossing (figure 32)....
-
New Construction
Dining and Work Surfaces -- Sections 226 and 902. The provisions regarding accessible routes in section 206.2.5 (Restaurants and Cafeterias) also apply to dining surfaces....
-
Technical Requirements for Accessible Hiker/Pedestrian Trails
Section 7.4 of FSTAG explains the accessibility requirements for trails, including trail surfacing, clear tread width, grade and cross slope, resting intervals, passing spaces, tread obstacles...
-
Transit Stops (R308.1) (Section-by-Section Analysis)
The surfaces of boarding and alighting areas and boarding platforms must comply with the technical requirements for surfaces (see R302.7)....
- Panda S.10 All Aluminum Lift & Slide System
- Hill-Rom Likorall™ 242 S Overhead Lift
- BraunAbility Century 2 Wheelchair Lift for School Buses, Cutaway Buses, and Paratransit Vans
-
Shower Spray Unit and Water: ADA Standard Section 608.6
Section 608.6 covers the current ADA Standards for the shower spray units and water in shower compartments.
-
1009.7.2 Separation
The fire-resistance-rated construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever...
-
1009.7.2 Separation
The fire-resistance-rated construction shall extend vertically from the ground to a point not less than 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the...
-
E.
Cinemark's auditoria with 300 seats or less, persons who use wheelchairs cannot access the seating on risers as the wheelchair spaces available to them are located on the traditional, sloped-floor...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor. ...
-
1.9.1.2
with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
608.5.1 Transfer Type Shower Compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...
-
4.21.6 Shower Unit
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
4.21.6 SHOWER UNIT
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
4.2.5 FORWARD REACH
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....