People with spinal cord injury can achieve and maintain a healthy lifestyle by doing exercises shown and described in how-to videos. Shepherd Center’s SCI-Ex App users can do these...
Search Results "Wheeled Mobility Device"
Commonly Searched Documents
- Shepherd Center’s SCI-Ex App
-
208.3.2 Residential Facilities, F208.3.2 Residential Facilities
208.3.2 Residential Facilities F208.3.2 Residential Facilities The final rule edits the references in these sections to the technical requirements for residential dwelling units with mobility...
-
228.2 Mail Boxes, F228.2 Mail Boxes
228.2 Mail Boxes F228.2 Mail Boxes The final rule edits the references in these sections to the technical requirements for residential dwelling units with mobility features to conform...
-
407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses....
-
§ 38.159(d)(1) Design load
shall restrain a force in the forward longitudinal direction of up to 2,000 pounds (8,880 N) per securement leg or clamping mechanism and a minimum of 4,000 pounds (17,760 N) for each mobility...
-
233.3.6 Dispersion (Exception 2), F233.3.5 Dispersion (Exception 2), F233.4.6 Dispersion (Exception 2)
Exception 2 does not require emergency transportable housing units required to provide mobility features to be dispersed among the various types of units in the facility or to provide choices...
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
4.10.6* DOOR PROTECTIVE AND REOPENING DEVICE
They shall be provided with a reopening device that will stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an object or person....
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
1002.6.2 Transfer Height
The height of transfer device seats shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
- The Accessibility Management Platform (AMP) - AMP for Mobile
-
2.4.1. Replacement Costs
The Final RA estimates the costs to replace captioning and audio description hardware and devices over the time frame of the analysis. ...
-
F245.2.1 Picnic Facilities with Two or Fewer Picnic Units
Where picnic facilities contain two or fewer picnic units, each picnic unit shall provide mobility features complying with F245.2....
- LiveEquipd
-
§ 38.125(d)(2) Wheelchair or mobility aid spaces
(2) Wheelchair or mobility aid spaces. Spaces for persons who wish to remain in their wheelchairs or mobility aids shall have a minimum clear floor space 48 inches by 30 inches....
-
§ 38.159(a)(2) Exception
provided at stations or other stops required to be accessible under regulations issued by the Department of Transportation, the bus is not required to be equipped with a vehicle-borne device...
-
2.1.4. Venue Type
The number of hardware units and individual devices required by the rulemaking are the building blocks of the cost estimation for the average movie theater of each venue type. ...
-
809.1 General
Residential dwelling units required to provide mobility features shall comply with 809.2 through 809.4....
-
F245.2.2 Picnic Facilities with More Than Two Picnic Units
Where picnic facilities contain more than two picnic units, at least 20 percent, but not less than two, of the picnic units shall provide mobility features complying with F245.2....