Besam SW200i overhead concealed swing door operator - beauty and durability The Besam SW200i-OHC overhead concealed pedestrian swing door operator provides an aesthetically pleasing...
Search Results "Side-Opening Door"
Commonly Searched Documents
- Besam SW200i Overhead Concealed Swing Door Operator
-
206.5 Doors, Doorways, and Gates
206.5 Doors, Doorways, and Gates. Doors, doorways, and gates providing user passage shall be provided in accordance with 206.5....
- D&D Technologies SureClose 57 Hydraulic Closer and Hinge
-
404.2.6 Doors in Series and Gates in Series
404.2.6 Doors in Series and Gates in Series....
- Besam SW200i Overhead Concealed Swing Door Operator for Dual Egress BIM
-
404 Doors, Doorways, and Gates
404 Doors, Doorways, and Gates...
- Besam PowerSwing Electro-hydraulic Swing Door Operator
- Besam SW200i-IG In Ground Swing Door Operator
-
4.5.4 Gratings
If gratings have elongated openings, then they shall be placed so that the long dimension is perpendicular to the dominant direction of travel (see Fig. 8(h))....
-
4.5.4 GRATINGS
If gratings have elongated openings, then they shall be placed so that the long dimension is perpendicular to the dominant direction of travel (see Fig. 8(h))....
-
Are closet doors and pantry doors required to comply?
Requirements for doors, doorways, and gates in §404 apply to those that provide “user passage” (§206.5). Doors serving walk-in closets or pantries must comply....
- Besam SW200i-IG In Ground Swing Door Operator, Center Pivot, Double Door - BIM
-
404.2.6 Doors in Series and Gates in Series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates swinging into the space....
-
4.13.5 Clear Width
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the opposite stop (see Fig. 24(a), (b), (c), and (d...
-
F206.5 Doors, Doorways, and Gates
Doors, doorways, and gates providing user passage shall be provided in accordance with F206.5....
-
206.5 Doors, Doorways, and Gates
Doors, doorways, and gates providing user passage shall be provided in accordance with 206.5....
-
Doors, Doorways and Gates [§206.5 and §404]
Doors, Doorways and Gates [§206.5 and §404] Compliance is required for doors, doorways, and gates providing user passage on accessible routes....
-
R218 Doors, Doorways, and Gates
R218 Doors, Doorways, and Gates The SNPRM would revise R218 to read as follows: R218 Doors, Doorways, and Gates....
-
4.13.5 CLEAR WIDTH
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the stop (see Fig. 24(a), (b), (c), and (d))....
-
1010.2.2 Hardware
Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11A or 11B shall not require tight grasping, tight pinching or twisting of the...
-
H. Door Maneuvering Clearance
On the pull side of each door (i.e.: entry door, connecting room door, bathroom doors and other passage doors) in every accessible guestroom/suite, are there at least 18" of clear floor...
-
404.2.6 Doors in Series and Gates in Series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates swinging into the space....
-
Maneuvering Clearance or Standby Power for Automatic Doors
door in emergencies....
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Scooter
These data depict the reaching abilities of scooter users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction...