The standards specify a maximum height (27”) for the leading edge of barriers so they are within cane sweep, but a minimum height is not specified. Curbs may be mistaken for a step...
Search Results "Raised Button"
-
Can curbs be used to indicate areas with less than 80” of vertical clearance?
-
F206.6.1 Existing Elevators
Where elements of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered...
-
Audible WALK indications
Audible WALK indications Audible WALK indications are broadcast from a speaker that is incorporated into the pedestrian pushbutton housing. When the pedestrian pushbutton is...
-
Vibrotactile WALK indications
Vibrotactile WALK indications Vibrotactile indications are transmitted by a vibrating plate or arrow on the housing of the pedestrian pushbutton. During WALK, the arrow or plate...
-
Issue 12: Audible beaconing
Issue 12: Audible beaconing Audible beaconing -- providing a louder audible WALK signal in order to provide directional guidance to pedestrians who are blind -- is not needed at...
-
Issue 14: Inspection of contractor’s work - Beware of field changes!
Issue 14: Inspection of contractor’s work - Beware of field changes! Figure 18: APS and curb ramps that were not installed as designed. Figure 19: Another view of the...
-
Issue 11: Good vibrations (vibrotactile indications)
Issue 11: Good vibrations (vibrotactile indications) APS device usability is compromised if the vibrotactile indicator doesn’t vibrate during the WALK. The vibrotactile indication...
-
Question 22
YES/NO 22. Are there any obstacles that block access to lift or elevator controls? Obstacles may include trash receptacles or cigarette...
-
206.6.1 Existing Elevators
Where elements of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered...
-
206.6.1 Existing Elevators
206.6.1 Existing Elevators. Where elements of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall...
-
Verify Electrical
VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes. Measure to top or bottom of...
-
Verify Electrical
VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes. Measure to top or bottom of...
-
11B-206.6.1 Existing elevators
Where elements of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered...
-
11B-206.6.1 Existing elevators
Where elements of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered...
-
F206.2.5 Restaurants and Cafeterias
In restaurants and cafeterias, an accessible route shall be provided to all dining areas, including raised or sunken dining areas, and outdoor dining areas....
-
206.2.5 Restaurants and Cafeterias
In restaurants and cafeterias, an accessible route shall be provided to all dining areas, including raised or sunken dining areas, and outdoor dining areas. EXCEPTIONS: 1....
- ADA Sign Depot Stairwell Floor Level Sign with Tactile Text and Grade 2 Braille - 12" x 12"
-
Issue 5: Tactile arrow (in line)
Braille beneath arrow is backwards version of the print version shown on label and is indented, rather than raised....
-
Limited-Use/Limited-Application Elevators, Destination-Oriented Elevators and Private Residence Elevators
Section 407.2.1.4 of the 2010 Standards includes an exception to the technical requirements for locating elevator call buttons for destination-oriented elevators....
-
11B-206.2.5 Restaurants, cafeterias, banquet facilities and bars
In restaurants, cafeterias, banquet facilities, bars, and similar facilities, an accessible route shall be provided to all functional areas, including raised or sunken areas, and outdoor...
-
11B-206.2.5 Restaurants, cafeterias, banquet facilities and bars
In restaurants, cafeterias, banquet facilities, bars, and similar facilities, an accessible route shall be provided to all functional areas, including raised or sunken areas, and outdoor...
-
Buttons: ADA Standard Section 407.4.7.1
Section 407.4.7.1 covers the current ADA Standards for designations and indicators on elevator car control buttons.
-
Section I: Elevators
(§407.4.1) I3 Are hallway elevator call buttons 48" high or lower?...
-
11B-206.2.5 Restaurants, cafeterias, banquet facilities and bars
In restaurants, cafeterias, banquet facilities, bars, and similar facilities, an accessible route shall be provided to all functional areas, including raised or sunken areas, and outdoor...