Toilet stall doors shall comply with 4.13....
Search Results "Pit Toilet"
-
4.17.5* DOORS
-
11B-604.2 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-604.2 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
4.17.5* Doors
Toilet stall doors, including door hardware, shall comply with 4.13....
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
604.2 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
604.2 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
Dispensers [4.16.6]
Dispensers [4.16.6] Toilet paper dispensers should be located below the side grab bar so that they do not obstruct use of this bar....
-
Doors: ADA Standard Section 604.8.1.2
Section 604.8.1.2 covers the current ADA Standards for wheelchair accessible compartment doors.
-
Bobrick ClassicSeries Recessed Sanitary Napkin Disposal and Toilet Tissue Dispenser B-3094 Elevations
Requires the Premium User plan or above. (Login or upgrade your account!)
-
H1
If a sign is provided at the toilet room entrance (e.g. Men, Women, Boys, Girls, etc.), is a sign with raised characters and Braille mounted on the wall adjacent to the latch?...
-
4.1.6(3)(c)
(c) The following toilet facilities, whichever is greater: (i) At least one toilet facility for each sex in the altered building complying with 4.22, Toilet Rooms, and 4.23, Bathrooms...
- ASI Global Partitions Stainless Steel Toilet Partitions
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet.
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet.
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet.
-
11B-202 Existing buildings and facilities
Toilet and bathing facilities are regulated in Section 11B-213 and include toilet rooms and bathing rooms....
-
604.2 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
604.2 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
Question 18
Are accessible public restrooms, toilet stalls, and fitting rooms unlocked when all other facilities are unlocked?...
-
11B-809.10.1 General
All toilet and bathing rooms on an accessible route within residential dwelling units with adaptable features shall comply with Sections 11B-809.7, 11B-809.8, 11B-809.10.6.4, 11B-809.10.7.3...
-
Priority 3: Toilet Rooms
Word Fillable Form (2.4MB) Word Non-Fillable Form (2.2MB) PDF Non-Fillable Form (0.7MB)
-
4.17.3 SIZE AND ARRANGEMENT
The size and arrangement of toilet stalls shall comply with Fig. 30(a). Toilet stalls with a minimum depth of 56 in (1420 mm) (see Fig. 30(a)) shall have wall-mounted water closets....