In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
Search Results "Hinge Side Clearance"
Commonly Searched Documents
-
11B-804.2.1 Pass through kitchen
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
Clearance: ADA Standard Section 604.9.2
Section 604.9.2 covers the current ADA Standards for clearances around children's use water closets.
- McGuire Manufacturing Co., Inc. 1149WC: Offset with 149 Flat Grid Strainer
-
Knee and Toe Space Depth
[See subsections ...]
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
Clearance: ADA Standard Section 604.3
Section 604.3 covers the current ADA Standards for clearances around water closets and in toilet compartments.
-
804.2.1 Pass Through Kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
(1) Transfer Surface Location for Diagnostic Equipment Used in the Supine, Prone, or Side-lying Position
These orientations are now identified as an end transfer surface and side transfer surface....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm)...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
307.4 Vertical Clearance
307.4 Vertical Clearance. Vertical clearance shall be 80 inches (2030 mm) high minimum....
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
804.2.1 Pass Through Kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls.
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls....
-
307.4 Vertical Clearance
Vertical clearance shall be 80 inches (2030 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2030 mm) high....
-
Figure M1: Overview of M301 Diagnostic Equipment for Use by a Patient in a Supine, Prone, or Side-Lying Position
[See subsections ...]
-
Vertical Clearance [4.6.5]
Vertical clearance of at least 98 inches is based on the height necessary for personally-owned vans....
-
11B-408.4.3 Platform to hoistway clearance
The platform to hoistway clearance shall comply with Section 11B-407.4.3....
-
11B-408.4.3 Platform to hoistway clearance
The platform to hoistway clearance shall comply with Section 11B-407.4.3....
-
11B-408.4.3 Platform to hoistway clearance
The platform to hoistway clearance shall comply with Section 11B-407.4.3....
-
Side Reach [4.2.6]
High and low reaches are based on a depth of reach no greater than 10 inches measured from the available clear floor space. It is important that clear floor space be available at...
-
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position....