Requests for extension of time must be submitted by July 26, 1992....
Search Results "Handrail Extension"
Commonly Searched Documents
-
Section 37.51 Key Stations in Commuter Rail Systems
-
FIGURE INDEX
Gates Figure 502.2 Vehicle Parking Spaces Figure 502.3 Parking Space Access Aisle Figure 503.3 Passenger Loading Zone Access Aisle Figure 504.5 Stair Nosings Figure 505.4 Handrail...
-
Attachment A: Violations Identified in the United States' Letter of Findings (Sept. 29, 2014)
[See subsections ...]
-
§ 37.47(c)(2)
(2) The FTA Administrator may grant an extension of this completion date for key station accessibility for a period up to July 26, 2020, provided that two-thirds of key stations are made...
-
R407.4 Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 915 mm (3.0 ft) minimum....
-
1009.3.2 Stairway width
Stairways shall have a clear width of 48 inches (1219 mm) minimum between handrails....
-
Sec.36.401(a)(2)(i)
(i) If the last application for a building permit or permit extension for the facility is certified to be complete, by a State, County, or local government after January 26, 1992 (or, in...
-
§ 36.401(a)(2)(i)
(i) If the last application for a building permit or permit extension for the facility is certified to be complete, by a State, County, or local government after January 26, 1992 (or, in...
-
Attachment J
Within 2 years, the City of Waukegan will make the following modifications to the Public Works and Public Works Addition: The handrails at the entrance ramp do not continue for...
-
Swimming Pools, Wading Pools & Spas
Word Fillable Form (2.8MB) Word Non-Fillable Form (2.6MB) PDF Non-Fillable Form (1.0MB)
-
1607A.8 Loads on handrails, guards, grab bars, seats and vehicle barriers
[See subsections ...]
-
11B-405.9.1 Reserved.
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
11B-405.5 Clear width
Handrails may project into the required clear width of the ramp at each side 3½ inches (89 mm) maximum at the handrail height. 3....
-
11B-405.5 Clear width
Handrails may project into the required clear width of the ramp at each side 3½ inches (89 mm) maximum at the handrail height....
-
Tread Obstacles on Outdoor Recreation Access Routes
When deciding whether handrails are necessary on outdoor stairs, also consider how many should be provided. For example, a few steps at an individual campsite may not need a handrail....
-
1015.3 Height
For occupancies in Group R-3, and within individual dwelling units in occupancies in Group R-2, where the top of the guard serves as a handrail on the open sides of stairs, the top of the...
-
11B-405.5 Clear width
Handrails may project into the required clear width of the ramp at each side 3½ inches (89 mm) maximum at the handrail height. 3. ...
-
The Basis for the 2010 ADA Standards Pocket Guide
Learn the basis of the 2010 ADA Standards Pocket Guide
-
1005.4 Clear Floor or Ground Space
At each location where there are railings, guards, or handrails complying with 1005.2.1, a clear floor or ground space complying with 305 shall be provided....
-
1005.4 Clear Floor or Ground Space
At each location where there are railings, guards, or handrails complying with 1005.2.1, a clear floor or ground space complying with 305 shall be provided....
-
Are public accommodations required to retrofit existing buildings by adding elevators?
A public accommodation generally would not be required to remove a barrier to physical access posed by a flight of steps, if removal would require extensive ramping or an elevator....
-
Maximum Slope at Ground Level
Designers are encouraged to consider edge protection and handrails on berms where there may be a drop-off. ...
-
907.5.2.3.3 Group R-2
The future extension of the existing wiring from the unit smoke alarm locations to required locations for visible appliances....