A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables....
Search Results "Fixed Table"
-
11B-813.2.1.2 Clearance
-
12. Personal Care Attendant (PCA)
disability, transportation agencies are not required to provide a personal care attendant or personal care attendant services to meet the needs of passengers with disabilities on paratransit or fixed...
-
11B-813.2.10 Door swing
within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance required for any fixture, and clearance required for adult changing tables...
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep...
-
Figure M2: M301.4 Lift Compatibility
(at Diagnostic Equipment for Use by a Patient in a Supine, Prone, or Side-Lying Position)
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
-
5.3.2 Transfer Sides Recommendations for M301
., foot of an examination table)....
-
General: ADA Standard Section 218.1
Section 218.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for transportation facilities.
-
Transportation Facilities: ADA Standard Section 218
Section 218 covers scoping requirements in the current ADA Standards for transportation facilities.
-
11B-218 Transportation facilities
[See subsections ...]
-
11B-218.1 General
Transportation facilities shall comply with Section 11B-218.
-
11B-218.1 General
Transportation facilities shall comply with Section 11B-218.
-
11B-218 Transportation facilities
[See subsections ...]
- Living Earth Crafts Cloud 9 Spa Treatment Table
-
M305.5 Head and Back Support (Section-by-Section Analysis)
One manufacturer asserted that this requirement was ambiguous and that he had to read it multiple times to understand it; however, this commenter also indicated that the tables it currently...
-
Clear Floor and Turning Space Inside Examination Rooms
The exam table must have sufficient clear floor space next to it so that an individual using a wheelchair can approach the side of the table for transfer onto it....
-
5.1.3 Transfer Surface Low Height Options for M301 and M302
The Committee shifted focus from a fixed height range between 17 to 19 inches as adjustability was accepted....
-
11B-249.1.2
Newly constructed commercial places of public amusement shall provide no fewer than one adult changing facility in compliance with Section 11B-813. ETA Editor's Note The...
-
604.8.1.1 Size
This space cannot be obstructed by baby changing tables or other fixtures or conveniences, except as specified at 604.3.2 (Overlap)....
-
604.8.1.1 Size
This space cannot be obstructed by baby changing tables or other fixtures or conveniences, except as specified at 604.3.2 (Overlap)....
-
604.8.1.1 Size
This space cannot be obstructed by baby changing tables or other fixtures or conveniences, except as specified at 604.3.2 (Overlap)....
-
12. What if I have two pools or a pool and a spa? Can I share a lift between pools?
Sharing non-fixed pool lifts between pools can pose safety risks to swimmers with disabilities because if a lift has been moved to another pool, a person with a disability might be unable...
- Living Earth Crafts Cloud 9 Cuvee Spa Treatment Table
-
7. In § 37.103 (b) and (c), remove the words “or an over-the-road bus,”
§ 37.103 [Amended] 7. In § 37.103 (b) and (c), remove the words “or an over-the-road bus,”.